Skip to main content

Electrophysiology lab efficiency comparison between cryoballoon and point-by-point radiofrequency ablation: a German sub-analysis of the FREEZE Cohort study

A Correction to this article was published on 01 March 2023

This article has been updated

Abstract

Background

Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA).

Methods

The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other.

Results

The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients’ characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively).

Conclusion

CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage.

Clinical trial registration NCT01360008 (first registration 25/05/2011).

Peer Review reports

Background

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and is an increasingly pressing issue for health care systems in Western Europe countries due to the ageing population. Currently, at least 8 million inhabitants of the European Union suffer from AF, and the revised lifetime risk for AF in individuals over 55 years old increased from 1 out of 4 to 1 out of 3 [1].

According to the European Society of Cardiology guidelines, AF catheter ablation is a well-established treatment for the prevention of AF recurrences and is recommended to improve AF symptoms in patients with paroxysmal or persistent AF [1]. The cornerstone of AF catheter ablation is the complete pulmonary vein isolation (PVI), and can be accomplished with radiofrequency point-by-point circumferential lesions or single-shot ablation devices like the cryoballoon [2, 3]. In Germany, an estimated number of 92,220 ablations were performed in 2018, an increase of more than 5% within one year, according to a yearly survey among several hundred electrophysiology units [4]. Out of 237 responding ablation centres, 27% of all facilities performed up to 100 ablations per year, and 17.6% more than 500. The increasing number of patients with AF is a challenge for physicians, hospitals and the healthcare system in Germany. Therefore, procedural efficiency is a key element to manage resources consumption in hospitals. The aim of this analysis is to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and irrigated tip point-by-point radiofrequency ablation (RFA), based on the FREEZE Cohort study.

Methods

FREEZE Cohort study design

The FREEZE Cohort study (NCT01360008) was a prospective, non-randomized, observational cluster cohort study that compared the effectiveness and safety of RFA and CBA, conducted in 42 experienced hospitals across eight countries [5]. Each centre was assigned as a RFA or a CBA study site, chosen according to the centre’s experience and preference. Patients who received a first ablation for symptomatic paroxysmal or drug-refractory persistent AF were eligible to participate. All enrolled patients were intended to be treated by the designated technique. The study design and the main results of the intention-to-treat analysis were presented in a previous publication [3].

The present analysis evaluates the consequences of differently distributed procedure times between CBA and RFA on schedules and utilisation of resources and staff. Only the procedures undergone in the participating centres across Germany were included as they included all RFA procedures and most of CBA procedures. The calculated metrics and model assumptions were adapted to be illustrative of German hospitals.

Analysis population

Patients who underwent a PVI-only approach were included in this analysis; PVI procedures with additional ablation lesions (e.g. linear lesions, ablation of complex fractionated atrial electrograms, right atrial flutter, and ablation at the AV node) were excluded. Focal RF touch-ups or treatment with two sizes of the cryoballoon needed in some CBA cases were not excluded.

The treatment groups were defined according to whether CBA or RFA was utilized for the initial ablation, as procedure times should be ascribed to the procedures that were actually completed to reflect clinical reality and to avoid an artificial setting. The crossover rate to any other technique was very low in both groups [3].

Discrete event simulation model

A discrete event simulation (DES) model was used to evaluate electrophysiology (EP) lab efficiency based on PVI procedure times reported in the FREEZE Cohort. EP lab efficiency for this analysis is defined as improvements in utilization gained from shorter and more predictable procedure times, which includes fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for additional EP lab usage.

DES is a method of simulating the behaviour and performance of a real-life process, facility or system, and has been used to model the efficient use of resources in various healthcare settings. These simulations are based on a stochastic time series of individual, granular events representative of realistic occurrences. Individuals and critical resources in the DES are treated distinctly from each other, having unique characteristics and memory, and are drawn from a detailed probabilistic characterization derived from real-world data and experience. SIMUL8 professional version 26.0 (SIMUL8 Corporation) was used for DES in this analysis.

DES model inputs

This DES aimed to model the impact of operational changes on German EP lab occupancy based on the variability of the ablation procedure start and stop times. In the model, the first PVI case was scheduled at 7:30 am, and three PVI cases were scheduled in a lab day using either the CBA system (Arctic Front™ Cardiac Cryoablation system, Medtronic, Inc.) or an irrigated point-by-point RFA system. The EP lab was modelled fully flexible scheduling: each procedure started as soon as the lab opened or the previous case was over [6]. Operational delays were assumed in the model, including: (1) room turnover time of 20 min and (2) patient delays between 0 and 15 min. No delay associated to the electrophysiologist was assumed in this model. EP lab overtime was counted when PVI procedures extended after 6:00 pm. Figure 1 provides a schematic diagram of the model and Table 1 provides the input values used in the model.

Fig. 1
figure 1

Schematic diagram of the discrete event simulation model. EP, electrophysiologist; CBA, cryoballoon ablation; RFA, irrigated point-by-point radiofrequency ablation; PVI, pulmonary vein isolation. The figure represents a schematic diagram of the discrete event simulation model. On each day, patients arrive at the EP lab for the PVI procedure and experience a one-time delay prior to being available for the case (including a “no delay” time option). When the patient is available, the case will proceed with a randomly selected procedure duration according to the FREEZE Cohort procedure time distribution. Once the procedure is over, the patient leaves the EP lab

Table 1 Discrete event simulation model parameters

The model used lab occupancy time, defined as the time the patient enters the EP lab until the patient exits it. Lab occupancy time includes both the ablation procedure time (sheath in/out) and non-procedural time during which the patient is in the EP lab, but the procedure is not ongoing. Procedure times were extracted from the FREEZE Cohort study and were separated between CBA and RFA. Non-procedural times were derived from the FAST-PVI study [7] and were similar for both CBA and RFA. Gamma curves were used to fit all procedure time probability distribution data.

DES model statistics

The length of the base case simulation was set to 1000 lab days to get a procedure time distribution in the model that follows the original one used, from the FREEZE Cohort study. A simulation over 1000 lab days results in an overall average procedure time at ± 1.5% from the FREEZE Cohort mean procedure time, with 95% confidence.

The 1000 lab days simulation was run repeatedly with different random combinations of number seeds, and the final metrics reported represent the overall average of means from these individual runs to ensure the results were not dependent on an arbitrary set of random numbers.

Model outputs were reported as the percent of days leading to overtime, the percent of days with lab time remaining at the end of the planned schedule and the cumulative overtime (hours) over the study period. EP labs have variability in operating parameters such as staff begin and end time, when overtime starts, and room turnover time. For the purposes of a consistent analysis, we have selected parameters generally representative of EP labs and created a simulation model representing efficiency gains in this illustrative EP lab operation.

In addition, sensitivity analyses were performed by individually varying single model inputs (while keeping all other inputs constant), including: (1) lab occupancy time, (2) room turnover time, (3) EP lab shift end, and (4) mean patient delay. Variable values used in the sensitivity analyses are provided in Additional file 1: Table S1. As the DES is stochastic in nature, a separate probabilistic sensitivity analysis was not performed.

Descriptive statistics

Binary and categorical data are reported as absolute numbers and frequencies, mean and standard deviation or median and quartiles are presented for continuous characteristics of patients treated with CBA and RFA. Procedure time is displayed as a box plot and histogram for both cohorts and the distributions are compared between patient groups by Wilcoxon rank-sum test. The treatment groups are also compared with regard to patient characteristics calculating p-values by Pearson chi-squared test and odds ratios with 95%-confidence intervals for binary variables and using Wilcoxon rank-sum test for ordinal and metrical variables. All tests are two-sided and statistical significance was defined as p < 0.05.

The association of patient characteristics with the procedure duration is assessed for CBA and RFA separately by comparing patients above and below a cut-off near the median. Standardized mean differences are calculated showing the direction and magnitude of the imbalance (Austin, Balance diagnostics). The documentation is more than 95% complete with regard to the main variables. No imputation of or adjustment for missing data was performed, with the number of available cases indicated as denominator of rates. Correlation within centre clusters was not taken into consideration. These statistical computations were performed using SAS version 9.4 (Cary, USA).

Results

Patient characteristics

In total, 1743 patients enrolled in German hospitals were treated by CBA and 1829 by RFA between April 2011 and February 2016. In CBA group, 138 (7.9%) received PVI plus additional lesions and 382 (20.9%) in RFA group. In RFA group, 67 patients treated with the anatomically-designed PVAC Gold RF catheter were excluded, as this analysis aims to compare point-by-point RFA to CBA. Moreover, 45 (CBA) and 36 (RFA) patients were not available for the analysis because of missing documentation of procedure time. Altogether, 1560 CBA patients and 1344 RFA patients from 30 experienced German centres were included in the analysis.

Relevant patient baseline characteristics are shown in Table 2. The proportion of persistent AF was significantly higher in RFA cohort, and these patients presented with more frequent and more severe symptoms and have more often AF as the current rhythm. Generally, individuals were slightly older, and coronary artery disease, valve disease, and heart failure were more commonly documented as a concomitant disease in this cohort, resulting in a higher risk profile as expressed by the CHA2DS2-VASc score. On the other hand, CBA patients were more often suffering from hypertensive heart disease.

Table 2 FREEZE Cohort patients characteristics

No baseline patient characteristic consistently predicted the duration of RFA or CBA procedure (Additional file 1: Table S2). Therefore, the analysis of the procedure durations was not adjusted for differences in baseline patient characteristics.

Procedural characteristics

The cryoablation catheter system (Medtronic, Inc.) was used in all CBA cases, 17% from the first generation (Arctic Front), 78% from the second generation (Arctic Front Advance), and 5% from the third generation (Arctic Front Advance ST). The cryoablation protocol (number of freeze cycles, freeze time, use real-time PV potential recordings) was left to the treating physician. In RFA cases, the manufacturers of the RF catheters were Biosense Webster (77.3%), St. Jude (20.8%), Biotronik (1.3%) and others (0.5%). In RFA and CBA groups, 3D electroanatomical mapping was used in 99.5% and 0.1%, respectively (p < 0.0001). Intracardiac echocardiography was used in 5.6% and 47.8% of the procedures (p < 0.0001), X-ray duration lasted 19 and 17 min (p < 0.001) and the dose-area product was 2187 and 1736 cGy*cm2 (p < 0.001) in average, for RFA and CBA procedures respectively. No information was available on the rate of contact-force-sensing catheters in RFA group [3]. The majority of patients were treated without any sedation or under analgo-sedation in CBA and RFA groups (99.7% vs 99.9% respectively, p = 0.53), and only a few patients were treated under endotracheal anaesthesia (0.3% and 0.1% respectively).

Figure 2 provides details on the distribution of CBA and RFA procedure durations in the FREEZE Cohort sample. The mean procedure time in CBA cohort was 38 min shorter than in RFA cohort, with smaller standard deviation (122.2 ± 39.4 vs 160.3 ± 53.5 min respectively, p < 0.0001). There was also less variability in procedure times between centres undertaking CBA than those with RFA (Fig. 3). Finally, CBA mean procedure time decreased by about an hour over time during the FREEZE Cohort study, whereas RFA mean procedure time seemed fairly steady over the study period (Fig. 4).

Fig. 2
figure 2

FREEZE Cohort procedure time details. The figure represents the box-plots for CBA and RFA procedure time distributions

Fig. 3
figure 3

FREEZE Cohort mean procedure times per center. The figure represents the average procedure time for CBA and RFA per center

Fig. 4
figure 4

FREEZE Cohort mean procedure times per year. The figure represents the average procedure time for CBA and RFA per year during FREEZE Cohort study period

DES model: base case results

Results have been consolidated through the repeated run of 1000 lab days simulation for both CBA and RFA. With 3 cases per day simulated for each ablation technique, 3000 PVI using CBA and 3000 using RFA were simulated within the model. A sample of simulated case time distributions is represented in Fig. 5.

Fig. 5
figure 5

PVI case begin and end times per day: subset simulated lab occupancy. A CBA centres and B RFA centres. The figure represents the begin and end times for a sampling of days from the simulation, with each contiguous vertical line indicating the time of lab occupancy (the bottom end indicating the case begin time and the top end indicating the case end time) for CBA (A) and RFA (B) procedures

The DES model demonstrated that of the 1000 simulated Cryo lab days, 257 (25.7%) days required overtime to complete the three PVI cases. In contrast, 707 (70.7%) of the simulated RF lab days required overtime to complete the three PVI cases. In total, the cumulative overtime associated with CBA was 253 h during the studied period whereas 1285 h of overtime were required to complete RFA PVI procedures. Overall, RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the course of 1000 PVI cases. The model also demonstrated that CBA was associated with 478 days with a remaining hour at the end of the EP lab shift, compared to 115 days with a remaining hour at the end of the lab day when using RFA (47.8% vs 11.5% days with one remaining hour, respectively). These results are represented in Fig. 6.

Fig. 6
figure 6

Discrete event simulation model results, 3 metrics after simulation of 1000 lab days. The Fig. 6 represents three DES model metrics after 1000 simulated lab days with PVI using CBA and 1000 using RFA. The metrics are the number of days with overtime, the number of days with an hour left at the end of the EP lab shift and the cumulative overtime in hours

DES model: sensitivity analyses results

The sensitivity analyses explored varying the simulation inputs. The results illustrated that the model outputs are most sensitive to procedure time. In all input scenarios, the advantage of CBA as compared to RFA was preserved for all model outputs. All sensitivity analyses and the results are available in the Additional file 1.

Discussion

Procedure times illustrated in this report from the FREEZE Cohort study demonstrate that PVI using CBA is a significantly shorter, more predictable and more efficient procedure than ablation using RFA. Furthermore, procedure times were more consistent across centres with CBA and so the impact of variability on EP lab efficiency was less pronounced. Also, CBA trend of decreasing procedure time over years during FREEZE Cohort study period was striking, and this characteristic is still observed today, even after many years of CBA use [8]. These findings are consistent with previously published studies [2, 9, 10].

Recent studies have used DES to model AF ablation. Kowalski [11] used lab occupancy times from the VALUE PVI trial to assess the economic impact of procedural efficiencies between CBA and RFA in the United States (US). In this analysis, CBA for paroxysmal AF was associated with a reduction of 36.2% in days with overtime, 92.7% less cumulative overtime hours, and an increase of 46.7% in days with time for an additional EP lab usage. Monnickendam [6] also compared the impact on average procedure consumptions of AF ablation with CBA and RFA via a DES model, using data from a single surgical centre in Belgium. The study demonstrated that 28.6% of RFA procedures are over 30 min longer than the median duration, compared to only 4.4% of CBA procedures. The authors concluded that the choice of AF ablation technology has a significant impact on the operating room efficiency and should be considered in decision-making. Kowalski [12] evaluated EP lab utilization with a DES model using the single-arm STOP Persistent AF trial data in the US, and demonstrated that using CBA to treat persistent AF patients confers EP lab efficiencies that can support an additional third PVI case in a lab day, as opposed to the standard of two in the US. The FREEZE Cohort analysis results are consistent with these previously published DES analyses: hospitals benefit from CBA through efficient use of the EP lab resources, including remaining time for physicians and staff, for the same volume of patients treated. While the extra hours preserved by using CBA instead of RFA are represented here by avoidance of overtime, it may not be overtime avoidance for every centre. However, completing PVI cases more quickly is likely to lead to meaningful advantages, whether it be for avoiding overtime or freeing up lab capacities. With more efficient CBA procedures particularly with streamlined protocols and the latest generation of the cryoballoon [8], there is opportunity for more than 3 PVI procedures to be undergone during an EP lab day. This analysis used German centers procedural data and applied an illustrative EP lab case. The efficiency profile of CBA proved by the present and previously published studies provides a reliable trend to other hospitals with a fully flexible scheduling, from geographies beyond Germany.

Unpredictable and long duration PVI procedures cause overtime which can be associated with an under-utilization of EP lab time and less optimal use of staff resources. Moreover, overtime can be a human resource issue for some hospitals, where the scheduled staff shifts cannot cover the overtime hours, particularly given the low physician and nurse to hospital bed ratios in Germany [13]. The additional hours of overtime with RFA compared to CBA could also represent incremental costs to the hospitals that remunerate overtime hours at a higher tarif than usual. Finally, overtime may contribute to a high turnover of EP lab staff and reduce the efficiency and effectiveness of the workforce in delivering high quality and safe care [14]. In addition to ensuring optimal patient care, employee satisfaction is an important consideration for the employers in a context of shortage of skilled health workers [13].

A previously published analysis of FIRE and ICE trial (NCT01490814) estimated that CBA was associated with meaningful and persistent cost-savings across multiple different healthcare systems, including a total cost-saving of €245,000 during the trial period for German system, due to fewer rehospitalizations, cardioversions and repeat ablations compared to RFA [15, 16]. The FREEZE Cohort study also demonstrated fewer all-cause rehospitalizations and repeat ablations with CBA compared to RFA in real-world settings [3]. Beyond substantial cost-savings for German payers, CBA is also a time-efficient procedure to treat AF patients, with an efficient use of EP lab resources in hospitals in the German healthcare setting.

Given the increasing prevalence of AF, it is important that the clinical community increases access to AF ablation and delivers rhythm control therapies in a timely fashion, particularly, if one considers that today only 5% of all AF patients undergo catheter ablation. The EAST-AFNET trial demonstrated that early rhythm control improves patient outcomes [17]. Moreover, the EARLY-AF [18], STOP AF First [19] and CRYO-First [20] trials illustrate that an early AF ablation with CBA is superior to anti-arrhythmic drug therapy in drug-naïve patients regarding recurrence of atrial tachyarrhythmia after one year. This evidence suggests that the demand for AF ablation is likely to increase even faster than AF prevalence. This additional strain on the healthcare system will reinforce the need to streamline all aspects of AF ablation procedures in order to ensure that patients are treated as efficiently, effectively and safely as possible.

Limitations

Firstly, the FREEZE Cohort study was not randomized, and patient groups were different at the baseline for some parameters. However, no baseline patient characteristic consistently predicted the duration of RFA or CBA procedure. Also, basing DES analysis on a real-world settings study data provides an added value for simulation results robustness. Secondly, there was no collected data from the FREEZE Cohort study to undertake direct comparisons of the measures predicted by the model: cumulative overtime, days with overtime and days with a remaining hour. Although, DES modelling benefit is to understand impacts that are not easily measured in the real world. This analysis did not address additional measures of EP lab efficiency, such as staffing levels and equipment logistics. The specific gains in efficiency for centres that have different operating parameters than what was chosen for this analysis might deviate, but the sensitivity analyses demonstrate that the gains are likely to be preserved in some form for all reasonable variations of the operating parameters. Thirdly, the FREEZE cohort study did not collect different levels of operators involved in the procedure. Level of experience can be a factor for the duration of the procedure, with less experience resulting in longer procedure times. This effect was addressed in the sensitivity analysis; the impact of reasonable variations in procedure times is explored in the Additional file 1: Fig. S4. The main results of the study remained true even with this variation. Fourthly, only German centres procedural data were included in this analysis to complete the simulation of one representative EP lab case. The vast majority of patients in both groups were treated under analgo-sedation or without any sedation. It remains unclear if the results can be transferred to settings with general anaesthesia. In addition, there are other procedure details that were not explicitly taken into account in the model. However, the variability in procedure times due to these details were reflected in the model, and the efficiency profile of CBA in this model is consistent with previously published studies [2, 9, 10]. Thus, this report results are expected to provide a reliable trend to other hospitals with a fully-flexible scheduling, from geographies beyond Germany. Also, radiation exposure was not included in the DES model, but the associated results from FREEZE Cohort were previously published [3]. Procedure times were collected from the FREEZE Cohort study, and are expected to be lower today because of the current efficiency of AF ablation procedures and based on the advanced ablation technology. The number of PVI per EP lab day, directly linked to the EP lab time per case, is also expected to be higher in most of the centres, however the EP lab efficiency benefit of CBA over RFA is expected to remain. Finally, no information on the rate of contact-force-sensing catheters applied in the RF group, which might potentially influence procedural parameters as well as acute and clinical outcomes, can be provided in our analysis.

Conclusion

FREEZE Cohort analysis confirms in real-world settings that CBA is faster and more predictable than RFA, and enables improvements in EP lab efficiency. The DES of the FREEZE Cohort data demonstrated the benefits of AF ablation procedures using the cryoballoon system, including fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage.

Availability of data and materials

The data underlying this article cannot be shared publicly due to privacy of the individuals that participated in the study. The datasets analysed during the current study are not publicly available due to privacy of the individuals that participated in the study but are available from the corresponding author on reasonable request.

Code availability

Software SIMUL8 professional version 26.0 (SIMUL8 Corporation).

Change history

  • 13 February 2023

    This article has been corrected since original publication; please see the linked erratum for futher details.

  • 01 March 2023

    A Correction to this paper has been published: https://doi.org/10.1186/s12872-023-03107-z

Abbreviations

AF:

Atrial fibrillation

PVI:

Pulmonary vein isolation

CBA:

Cryoballoon ablation

RFA:

Radiofrequency ablation

DES:

Discrete event simulation

EP:

Electrophysiology

US:

United States

References

  1. Hindricks G, et al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2020;42:373–498.

    Article  Google Scholar 

  2. Kuck K-H, et al. Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N Engl J Med. 2016;374(23):2235–45.

    Article  PubMed  Google Scholar 

  3. Hoffmann E, et al. Outcomes of cryoballoon or radiofrequency ablation in symptomatic paroxysmal or persistent atrial fibrillation. Europace. 2019;21(9):1313–24.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Deutscher Herzbericht 2019 [German Heart Report 2019].

  5. Hoffmann E, et al. Design and baseline patient characteristics of the prospective, observational, multicenter and multinational cohort study comparing radiofrequency with cryoablation for pulmonary vein isolation in patients with atrial fibrillation—the Freeze Cohort study. Int J Clin Med. 2014;05(19):1161–72.

    Article  Google Scholar 

  6. Monnickendam G, de Asmundis C. Why the distribution matters: Using discrete event simulation to demonstrate the impact of the distribution of procedure times on hospital operating room utilisation and average procedure cost. Oper Res Health Care. 2018;16(20–28):2018.

    Google Scholar 

  7. Klein G, et al. Comparison of ‘anatomically designed’ and ‘point-by-point’ catheter ablations for human atrial fibrillation in terms of procedure timing and costs in German hospitals. Europace. 2015;17(7):1030–7.

    Article  PubMed  Google Scholar 

  8. Iacopino S, et al. A comparison of acute procedural outcomes within four generations of cryoballoon catheters utilized in the real-world multicenter experience of 1STOP. J Cardiovasc Electrophysiol. 2020;31(1):80–8.

    Article  PubMed  Google Scholar 

  9. Ravi V, et al. A systematic review and meta-analysis comparing second-generation cryoballoon and contact force radiofrequency ablation for initial ablation of paroxysmal and persistent atrial fibrillation. J Cardiovasc Electrophysiol. 2020;31(10):2559–71.

    Article  PubMed  Google Scholar 

  10. Mörtsell D, et al. Cryoballoon vs. radiofrequency ablation for atrial fibrillation: a study of outcome and safety based on the ESC-EHRA atrial fibrillation ablation long-term registry and the Swedish catheter ablation registry. Europace. 2019;21(4):581–9.

    Article  PubMed  Google Scholar 

  11. Kowalski M, et al. Using discrete event simulation to model the economic value of shorter procedure times on EP Lab efficiency in the VALUE PVI study. J Invasive Cardiol. 2016;28(5):176–82.

    PubMed  Google Scholar 

  12. Kowalski M, Su WW, Holbrook R, Sale A, Braegelmann KM, Calkins H. Impact of cryoballoon ablation on electrophysiology lab efficiency during the treatment of patients with persistent atrial fibrillation: a sub-analysis of the STOP persistent AF study impact of cryoballoon ablation on electrophysiology lab efficiency duri. J Invasive Cardiol. 2021;33:E522–30.

    PubMed  Google Scholar 

  13. OECD/European Observatory on Health Systems and Policies. Germany: Country Health Profile 2019, state of health in the EU. Paris: OECD Publishing; 2019. https://doi.org/10.1787/36e21650-en.

  14. Griffiths P, et al. Nurses’ shift length and overtime working in 12 European countries: the association with perceived quality of care and patient safety. Med Care. 2014;52(11):975–81.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Chun KRJ, et al. The impact of cryoballoon versus radiofrequency ablation for paroxysmal atrial fibrillation on healthcare utilization and costs: an economic analysis from the FIRE AND ICE trial. J Am Heart Assoc. 2017;6(8):e006043.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Kuck KH, et al. Cryoballoon or radiofrequency ablation for symptomatic paroxysmal atrial fibrillation: reintervention, rehospitalization, and quality-of-life outcomes in the FIRE and ICE trial. Eur Heart J. 2016;37(38):2858–65.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Kirchhof P, et al. Early rhythm-control therapy in patients with atrial fibrillation. N Engl J Med. 2020;383(14):1305–16.

    Article  PubMed  Google Scholar 

  18. Andrade JG, et al. Cryoablation or drug therapy for initial treatment of atrial fibrillation. N Engl J Med. 2020;384:305–15.

    Article  PubMed  Google Scholar 

  19. Wazni OM, et al. Cryoballoon ablation as initial therapy for atrial fibrillation. N Engl J Med. 2020;384:316–24.

    Article  PubMed  Google Scholar 

  20. Kuniss et al. Catheter cryoablation versus antiarrhythmic drug as first-line therapy of paroxysmal atrial fibrillation (Cryo-FIRST). Presented at the German Cardiac Society conference DGK 2020.

Download references

Acknowledgements

The authors would like to thank Kelly Bragt and Alicia Sale from Medtronic for providing support on the analyses and model validation, and Steffen Schneider from IHF for providing support on the analyses and the manuscript. The authors would also like to thank the other members of the FREEZE Cohort Study, K. Wegscheider, T. Ouarrak, T. Massa, G. Sabin, A. Franke, S. G. Spitzer, S. Willems, T. Dierk, J. K. R. Chun, R. Borchard, K. H. Seidl, R. Zahn, G. Groschup, J. Brachmann, J. H. Gerds-Li, J. Schrickel, T. Lewalter, W. Moshage, L. Eckardt, W. Jung, P. Kremer, B. Schumacher, L. Lickfett, T. Münzel, T. Deneke, D. Q. Nguyen. This analysis has been presented to the DGK 88th Annual Conference April 2022. Clinical Research in Cardiology (2022) 111:592. https://dgk.org/kongress_programme/jt2022/abstracts/aV1041.html?q=freeze.

FREEZE Cohort Study Investigators

15L. Q. Wu, 16A. Garcia-Alberola, 17T. Massa, 18G. Sabin, 19A. Franke, 20J. J. Souza, 21A. Stanley, 22S. G. Spitzer, 23S. Willems, 24T. Dierk, 25K. R. J. Chun, 26R. Borchard, 27K. H. Seidl, 28R. Zahn, 29G. Groschup, 30I. W. P. Obel, 31J. Brachmann, 32J. H. Gerds-Li, 33R. R. Gopal, 34J. Schrickel, 35T. Lewalter, 36A. Stanley, 37W. Moshage, 38L. Eckardt, 39W. Jung, 40P. Kremer, 41A. Lubinski, 42B. Schumacher, 43L. Lickfett, 44T. Münzel, 45C. Steinwender, 46M. Efremidis, 47T. Deneke, 48D. Q. Nguyen.

15Shanghai Rui Jin Hospital, Shanghai, China; 16Univ. Hospital Virgen d.l. Arrixaca, Murcia, Spain; 17Klinikum Frankfurt Höchst, Frankfurt, Germany; 18Elisabeth-Krankenhaus Essen, Essen, Germany; 19Klinikum Siloah, Hannover, Germany; 20Mission Hospital Inc., Ashville, NC, USA, 21Sunninghill Hospital 1, Sandton, South Africa; 22Praxisklinik Herz und Gefaesse, Dresden, Germany; 23Univ. Herzzentrum Hamburg-Eppend., Hamburg, Germany; 24Universitätsklinikum Heidelberg, Heidelberg, Germany; 25Cardioangiologisches Centrum Bethanien, Frankfurt, Germany; 26Herzzentrum Duisburg, Duisburg, Germany; 27Klinikum Ingolstadt, Ingolstadt, Germany; 28Klinikum Ludwigshafen, Ludwigshafen, Germany; 29Klinikum Aschaffenburg, Aschaffenburg, Germany; 30Milpark Hosp., Johannesburg, South Africa; 31Klinikum Coburg, Coburg, Germany; 32Deutsches Herzzentrum Berlin, Berlin, Germany; 33Panorama Medi-Clinic, Cape Town, South Africa; 34Universitätsklinikum Bonn, Bonn, Germany; 35Isar Herzzentrum, Munich, Germany; 36Sunninghill-Hospital 2, Sandton, South Africa; 37Klinikum Traunstein, Traunstein, Germany; 38Universitätsklinikum Münster, Münster, Germany; 39Schwarzwald-Baar-Klinikum, Villingen-Schwenningen, Germany; 40Albetinen-KH, Hamburg, Germany; 41Medical University of Gdańsk, Poland; 42Westpfalz-Klin., Kaiserslautern, Germany; 43Städt. Klin. Mönchengladbach, Mönchengladbach, Germany; 44Universitätsklinikum Mainz, Mainz, Germany; 45Allg. Krankenhaus Linz, Linz, Austria; 46Evangelismos Gen. Hosp., Athen, Greece; 47Herz-/Gefäßklinik Bad Neustadt, Bad Neustadt a. d. Saale, Germany; 48St. Vinzenz Hospital Köln-Nippes, Cologne, Germany.

Funding

Open Access funding enabled and organized by Projekt DEAL. This work was supported by Medtronic Inc.

Author information

Authors and Affiliations

Authors

Consortia

Contributions

AM and FS have participated in the conception, design, interpretation of the results, and writing of the manuscript. RRT, MK, GN, JT, DA, HW, CS, JF, UD, MH, JS, EH and KHK have participated in the design, interpretation of the results and writing the manuscript. RH and PLC have participated in the conception, design and writing of the manuscript. All authors read and approved this manuscript.

Corresponding author

Correspondence to Andreas Metzner.

Ethics declarations

Ethics approval and consent to participate

The local ethics review committees of all the centres approved the study, and informed consent was obtained from all patients. The study complies with the Declaration of Helsinki, and data were collected prospectively. The ethics review committees that approved the study were the following: Ethik-Kommission -Med. Fak. Bonn, Rheinische Friedrich-Wilhelms-Universität, Bonn, Germany; Ethik-Kommission bei der Medizinischen Fakultät, Julius-Maximilians-Universität Würzburg, Würzburg, Germany; Ethik-Kommission, Albert-Ludwigs-Universität Freiburg, Freiburg, Germany; Ethik-Kommission der Ärztekammer Westfalen-Lippe und der Medizinischen Fakultät der Westfälischen Wilhelms Universität, Münster, Germany; Sächsiche Landesärztekammer, Dresden, Germany; Ärztekammer Nordrhein, Düsseldorf, Germany; Ethik-Kommission der Ärztekammer Hamburg, Hamburg, Germany; Ethikkommission der Med. Fak. Heidelberg, Heidelberg, Germany; Ethik-Kommission der Landesärztekammer Rheinland-Pfalz, Mainz, Germany; Ethik-Kommission der Bayerischen Landesärztekammer, München, Germany; Landesärztekammer Baden-Württemberg, Stuttgart, Stuttgart, Germany; Ethik-Kommission OLVG, Amsterdam, Netherlands; Ethik-Kommission Arrixaca, El Palmar (Murcia), Spain; Pharma-ethics, Lyttelton, Zuid Africa; Ethikkommission des Landes Oberösterreich, Linz, Austria.

Consent for publication

Not applicable.

Competing interests

AM reports consulting, travel and lecturer fees from Cardiofocus and Medtronic, outside the submitted work. FS reports speaker fees from Medtronic, Astra Zeneca, Bristol-Myers-Squibb outside the submitted work, and educational support from Pfizer. RT reports research grant from Abbott and Medtronic, and speaker bureau for Abbott, Boston Scientific, Biosense Webster and Medtronic, outside the submitted work. MK reports speaker fees from Abbott and Medtronic; proctoring, consultancy and advisory board services for Medtronic, outside the submitted work. JT reports lecture honoraria from Medtronic. PLC is employed by Medtronic. RH is employed by and stockholder of Medtronic. MH and JS report that their employer, Stiftung IHF, received financial support from Medtronic for the conduct of the FREEZE Cohort study and for statistical analyses of the present work. EH reports that her department received compensation for participation in clinical research trials outside the submitted work, from Abbott, Bayer, Biotronik, Boehringer Ingelheim, Edwards, Elixier, Medtronic and Stentys. KHK reports grants and personal fees from Biosense Webster, Medtronic, Abbott Vascular and Impulse Dynamics outside the submitted work. GN, DA, HW, CS, JF and UD report no involvement that might raise the question of bias in the work reported or in the conclusions, implications, or opinions stated.

Informed consent

Informed consent was obtained from all patients in the FREEZE Cohort study.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1

. Figure S1. Procedure time distribution for Cryoballoon ablation (CBA) procedures (FREEZE Cohort, German CBA centres). Figure S2. Procedure time distribution for point-by-point radiofrequency ablation (RFA) procedures (FREEZE Cohort, German RFA centres). Figure S3. Plot gamma curves for procedure time distribution (FREEZE Cohort, German centres). Table S1. DES model parameters used for the study (Base Case) and the sensitivity analyses. Figure S4. Sensitivity analyses results. Table S2. Patients baseline characteristics below and above median procedure time for CBA and RFA.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Metzner, A., Straube, F., Tilz, R.R. et al. Electrophysiology lab efficiency comparison between cryoballoon and point-by-point radiofrequency ablation: a German sub-analysis of the FREEZE Cohort study. BMC Cardiovasc Disord 23, 8 (2023). https://doi.org/10.1186/s12872-022-03015-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12872-022-03015-8

Keywords