Skip to main content

Short- to mid-term outcomes after transcatheter aortic valve replacement in patients with ascending aorta dilation: a single-centre retrospective analysis

Abstract

Objectives

Ascending aorta dilation (AAD) is frequently associated with aortic stenosis (AS). This study investigated the procedural and clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with AAD for tricuspid AS.

Methods

This is a single-centre retrospective study that included patients with tricuspid AS and who underwent TAVR between January 1, 2018 and December 31, 2021. A total of 239 patients met the inclusion criteria. The ascending aortic diameter was measured on computed tomography (CT) scans before TAVR, and AAD was identified as a maximal ascending aortic diameter of ≥ 40 mm. The outcomes were in line with the Valve Academy Research Consortium (VARC)-3 criteria.

Results

Self-expandable (SE) valves were used in 88.7% of the total cohort (89.0% in the AAD group and 88.6% in the non-AAD group). Seventy-three patients (30.5%) were diagnosed with concomitant AAD (mean age 73.7 ± 7.3 years, 57.5% male). The median ascending aortic diameter was 36.0 mm (interquartile range [IQR]: 34.0–37.0 mm) in the non-AAD group and 44.0 mm (IQR: 42.0–46.0 mm) in the AAD group (p < 0.001). The baseline characteristics were comparable across the groups. No significant difference was observed in cumulative all-cause mortality at 30 days (2.4% vs. 1.4%, p = 0.609), 1 year (9.2% vs. 5.0%, p = 0.191), or 3 years (13.1% vs. 9.5%, p = 0.201) between the non-AAD and AAD groups. The device success rate was not different between the non-AAD and AAD groups (74.7% vs. 82.2%, p = 0.205). The multivariable analysis identified prior percutaneous coronary intervention, prior stroke, and length of intensive care unit as independent predictors of 3-year all-cause mortality among the total cohort.

Conclusion

AAD does not appear to be associated with the procedural and mid-term clinical outcomes in patients undergoing TAVR.

Peer Review reports

Introduction

Transcatheter aortic valve replacement (TAVR) is now widely used in the management of high-risk and inoperable patients with tricuspid aortic stenosis (AS) [1, 2]. Aortic stenosis sometimes occurs concurrently with ascending aorta dilation (AAD) [3, 4] Patients with AAD often require surgical correction to prevent aortic dissection or rupture [5, 6]. The American College of Cardiology (ACC) Foundation guidelines recommended concomitant surgery when the ascending aortic diameter was > 45 mm [6], which cannot be applied in the TAVR procedure. However, as the indications for TAVR expand, more patients with AAD are being referred to have the procedure [7]. Almost 1% of patients with aortic stenosis present with thoracic aortic aneurysm in America [8]. The safety and feasibility of TAVR for patients with AAD deserve to be illustrated.

Self-expandable (SE) valves are characterized by a longer stent frame design, and the radial forces of the device are present at both the inflow and outflow levels, which may cause them to be challenging to use in patients with AAD [9]. A previous study concluded that a larger AAD was the most relevant predictor of device failure after SE valve implantation [9]. In addition, the Society of Cardiovascular Computed Tomography (SCCT) guidelines recommend that the proximal ascending aortic diameter measured by multidetector CT (MDCT) should not exceed 40–43 mm for SE valves [10]. However, SE-valves were used in most of the patients with AAD in this study, and the procedural and clinical outcomes of these patients deserve attention.

We initially thought that the dilation of the ascending aorta may not affect the prognosis of TAVR patients according to prior studies. The aim of the present study was to evaluate the procedural and clinical outcomes in patients with AAD compared to those without AAD undergoing TAVR.

Materials and methods

Patient population

Patients with tricuspid AS undergoing TAVR between January 1, 2018 and December 31, 2021 at our institution were included in the present study. The TAVR indications were as follows: (I) patients with intermediate- to high-risk aortic valve disease and a Society of Thoracic Surgeons risk (STS) score > 4; (II) patients who were aged ≥ 65 years; (III) patients with no contraindication to anticoagulation; (IV) patients were not at the acute stage of cerebrovascular events; and (V) patients without coronary heart disease requiring simultaneous revascularization. The following patients were excluded: (I) patients with any previous cardiovascular surgery; (II) patients with a bicuspid aortic valve; (III) patients with pure aortic regurgitation; and (IV) patients with poor MDCT imaging quality. This study was approved by the Medical Ethics Review Committee of Fuwai Hospital, and the requirement for informed consent was waived by the Medical Ethics Review Committee of Fuwai Hospital for the nature of a retrospective analysis.

Transcatheter aortic valve replacement procedure

TAVR was performed in a hybrid operating room by the cardiology team, and the patients were placed under general anaesthesia or were given local anaesthesia and were monitored by anaesthesiologists. All patients underwent TAVR after discussions with the multidisciplinary cardiology team, and the access site and the type of prosthesis were determined thereafter. Transfemoral access was preferred in all patients who met the criteria unless the prosthesis size and the calcification and atheroma of the aorto-iliofemoral artery were considered. All TAVR procedures were performed according to the established standards via the transfemoral, trans-carotid, or trans-subclavian approach and by using contemporary devices, such as the implantation of SE valves (Venus-A [Venus Medtech, Hangzhou, China], VitaFlow [Microport, Shanghai, China], TaurusOne [Peijia Medical, Suzhou, China]) [11,12,13] or balloon expandable (BE) valves (Sapien 3 [Edwards Lifesciences, Irvine, California], Sapien XT [Edwards Lifesciences, Irvine, California]) [14, 15].

Data collection

All patients underwent transthoracic echocardiography (TTE) and MDCT pre-TAVR. MDCT images were reconstructed with mid-systolic data using 3MENSIO Valves software (version 9.0, 3mensio Medical Imaging BV, Bilthoven, the Netherlands) [16] and were analysed by a dedicated core laboratory that included personnel who were blinded to the patient information and outcome data at our institution. The ascending aorta height was defined as the cross-sectional area 40 mm above the plane of the aortic annulus, as previously described [10]. The ascending aortic diameter was measured by the following method: (short axis aortic diameter + long axis aortic diameter)/2. Ascending aorta dilation was defined as a maximal ascending aortic diameter of ≥ 40 mm [4, 17]. The baseline characteristics and procedural and hospitalization data were retrospectively recorded manually from the institutional electronic medical record system and were entered into a dedicated database. All data were anonymized, systematically collected and assessed for quality.

Follow-up and end points

All endpoints in this study were defined in accordance with the Valve Academic Research Consortium (VARC)-3 criteria [18]. The primary end point of the study was 3-year all-cause mortality. The secondary endpoints were 30-day and 1-year all-cause mortality. Other endpoints included technical success, device success, all stroke, myocardial infarction, VARC type ≥ 2 bleeding, new permanent pacemaker implantation, aortic reintervention or surgery, rehospitalization, acute kidney injury (stage 2–4), paravalvular leakage, cardiac tamponade, and aortic dissection. The patients were followed up until May 31, 2022, by outpatient visits and telephone interviews. No patient was lost to follow-up in this study. The median follow-up time was 588 days (interquartile range [IQR]: 384 to 1014 days).

Statistical analysis

All continuous variables were tested for normality using the Shapiro‒Wilk test. Continuous variables were presented as the mean ± standard deviation (SD) and compared using Student’s t test or as the medians (25th–75th quartile) and were compared using the Mann‒Whitney U test. Categorical variables are presented as numbers and percentages and were compared using the Chi-square test or Fisher’s exact test. Periprocedural, early and late mortality were calculated using Kaplan‒Meier survival analysis, and the log-rank test was used for comparisons between the groups. To identify independent predictors of 3-year all-cause mortality among the total cohort, all variables with a p value < 0.10 in the univariate analysis were included in a stepwise multivariable Cox regression model. The proportional hazard assumption was confirmed by examination of log (−log [survival]) curves and by testing of partial (Schoenfeld) residuals, and no relevant violations were found. The estimated hazard ratio (HR) with 95% confidence interval (CI) was provided by Cox regression analysis. All tests were 2-sided, and p values < 0.05 were considered to be statistically significant. All statistical analyses were performed using SPSS software version 26.0 (IBM, NY, USA) and R software version 4.1.0 (available at http://www.r-project.org).

Results

Baseline characteristics

A total of 359 patients underwent TAVR during the study period at our institution (Fig. 1). A total of 120 patients were excluded according to the criteria (18 patients underwent previous heart valve surgeries or had interventions, 68 patients had a bicuspid aortic valve, 29 patients had pure native aortic regurgitation, and 5 patients had incomplete or poor MDCT imaging data). Therefore, a total of 239 patients with tricuspid AS were included in the present study. Seventy-three patients were diagnosed with AAD (mean age 73.7 ± 7.3, 57.5% male) and had an ascending aortic diameter of 40–50 mm. A total of 166 patients were diagnosed with non-AAD (mean age 73.1 ± 7.3, 51.8% male). The baseline characteristics were well balanced across the two groups (Table 1). Most patients were severely symptomatic (71.2% of the AAD group and 69.3% of the non-AAD group were NYHA functional class III or IV). The patients were at an intermediate risk as predicted by the STS score (median and interquartile range: 6.0 [5.0–7.0] % in the non-AAD group and 6.0 [5.0–7.0] % in the AAD group, p = 0.901). The haemodynamic severity and proportion of patients with aortic calcification of tricuspid AS were comparable between the two groups according to the echocardiographic and MDCT assessments. The ascending aortic diameters measured by MDCT were different (median and interquartile range: 36.0 [34.0–37.0] mm in the non-AAD group and 44.0 [42.0–46.0] in the AAD group, p < 0.001).

Fig. 1
figure 1

The flowchart of patient inclusion and exclusion. TAVR, transcatheter aortic valve replacement; MDCT, multidetector computed tomography; AAD, ascending aorta dilation

Table 1 Baseline characteristics

Procedural data and results

The procedural data and results are summarized in Table 2, and no significant differences were observed between the non-AAD and AAD groups. Emergency surgery was performed in 9 patients (5.4%) in the non-AAD group and in 2 patients (2.7%) in the AAD group. A total of 137 patients (82.5%) in the non-AAD group and 60 patients (82.2%) in the AAD group were under general anaesthesia during the procedure. The most frequent access site was via the transfemoral approach (96.4% of the patients in the non-AAD group and 94.5% of the patients in the AAD group). An SE-valve was used in the majority of the patients undergoing TAVR, and it was used in 147 patients (88.6%) in the non-AAD group and 65 patients (89.0%) in the AAD group. Balloon postdilation was more common in the AAD group (23.3% vs. 12.0, p = 0.027). Postprocedural aortic regurgitation grade ≥ moderate was present in 2 patients (1.2%) in the non-AAD group and 1 patient (1.4%) in the AAD group. Six patients (3.6%) in the non-AAD group and 1 patient (1.4%) in the AAD group underwent conversion to open surgery. The proportion of patients who underwent implantation of a second valve was not significantly different between the non-AAD group (30 patients, 18.1%) and the AAD group (10 patients, 13.7%, p = 0.404). The left ventricular ejection fraction at discharge was not different between the non-AAD group and AAD group (p = 0.435).

Table 2 Procedural data and results

Clinical outcomes

The technical success was 80.1% in the non-AAD group and 84.9% in the AAD group, but no significant difference was observed (p = 0.377). The device success was 74.7% in the non-AAD group and 82.2% in the AAD group (p = 0.205). Cumulative all-cause mortality at 30 days, 1 year, and 3 years was 2.4%, 9.2%, and 13.1% in the non-AAD group and 1.4%, 5.0%, and 9.5% in the AAD group, respectively. There were no significant differences in periprocedural mortality, early mortality, and late mortality between the non-AAD and AAD groups. The causes of mortality are shown in Table 3. Kaplan‒Meier survival curves of all-cause mortality between the two cohorts are shown in Fig. 2. Other clinical endpoints, such as all stroke, myocardial infarction, VARC type ≥ 2 bleeding, new permanent pacemaker implantation, aortic reintervention or surgery, rehospitalization, significant paravalvular leakage, and acute kidney injury (stage 2–4), were also comparable between the groups. Cardiac tamponade and aortic dissection were not observed in either group (Table 3).

Fig. 2
figure 2

Kaplan‒Meier survival curves of all-cause mortality between the non-AAD and AAD groups. AAD, ascending aorta dilation

Table 3 Clinical outcomes

In the multivariable analysis (Table 4), the factors that had been identified as independent predictors of 3-year all-cause mortality among the total cohort were prior percutaneous coronary intervention (HR: 2.92; 95% CI: 1.15 to 7.42; p = 0.024), prior stroke (HR: 3.42; 95% CI: 1.37 to 8.54; p = 0.009), and length of intensive care unit (HR per 1 day increase: 1.07; 95% CI: 1.04 to 1.10; p < 0.001).

Table 4 Predictive factors of all-cause mortality in the total cohort

Discussion

The key findings of our study were as follows: patients with AAD accounted for almost one-third of the overall population; the prevalence of patients with SE-valve was 88.6% in the non-AAD group and 89.0% in the AAD group, which are significantly higher proportions than those that have been previously reported for patients with TAVR [19]; none of the procedural and clinical outcomes were associated with AAD.

AAD is a common disorder in patients with AS, occurring in 1/5 to 1/4 of these patients [20,21,22]. However, the proportion in the present study was higher, with nearly one-third of the patients with AAD undergoing TAVR. To date, open surgery remains the standard treatment for patients with AAD. It is widely accepted that endovascular repair can treat descending aortic pathologies; however, its use for aortic arch and ascending aortic pathologies remains undefined and limited [23]. The TAVR procedure concomitant with endovascular intervention for AAD is unknown. With the expanding indications for TAVR, an increasing number of patients with tricuspid AS and concomitant AAD may receive TAVR treatment, especially those with an intermediate or a high surgical risk [7]. TAVR is a more minimally invasive treatment, but whether patients with AAD can benefit from it and whether AAD should become a new powerful risk stratification criterion for TAVR need to be considered.

According to previous studies [24, 25], patients with tricuspid AS with a concomitant ascending aorta diameter of 40–50 mm are at low risk of adverse aortic events after isolated aortic valve replacement. A conservative therapy strategy for AAD at the time of aortic valve surgery was recommended. For patients undergoing TAVR, similar studies showed that AAD did not increase the intraprocedural risk of adverse aortic events, nor did it affect mid-term survival [7, 19]. However, these studies did not compare the causes of death and other clinical outcomes in detail, and selection bias might exist. In our study, the baseline characteristics of the two groups were well balanced and comparable, and no differences were observed in technical success, device success, periprocedural, early and late mortality. All these results suggested that dilation of the ascending aorta may not affect the prognosis of TAVR patients. However, another large observational study showed that AAD was an independent risk predictor for 2-year all-cause mortality [26], which is a result that was obviously different from other studies. This may be due to the large sample size of the study. It needs to be noted that the diameter of the ascending aorta in these studies was mainly between 40 and 50 mm. There is a lack of relevant research evidence for patients with ascending aortic diameter ≥ 50 mm. Therefore, caution should be exercised in extrapolating these conclusions, especially when the current findings still remain controversial.

In theory, the SE valve needs to be closely attached to the valvular-aortic complex at both the inflow and outflow levels to obtain a sufficient radial force to ensure the stability of the valve position and to avoid paravalvular leak and valve malposition [9]. Therefore, when using SE valves, it is difficult for the outflow stent frame to be closely attached to the dilated ascending aorta for patients with AAD, and because of this, the stability of the prosthesis will be greatly reduced after deployment, thereby increasing the risk of paravalvular leak and the need for a second valve, which may affect long-term prognosis. The CHOICE randomized clinical trial suggested that there was a significantly lower device success of patients with SE-valves than with BE-valves [27]. An observational study also showed that increased diameter of the ascending aorta was an independent predictor of unsuccessful device implantation of TAVR following the use of the SE-valve [9]. However, in this study, an SE-valve was used in nearly 90% of the patients in both groups, but there were no significant differences in the procedural and clinical outcomes between the AAD and non-AAD groups. Furthermore, valve type was not an independent predictor of 3-year all-cause mortality among the total cohort. Based on the results of our study, the SE-valve seems to be safe and feasible in patients with AAD. However, there are many factors such as the proportion of oversize, aortic root angulation and depth of the implanted valve that need to be corroborated by more detailed studies in the future.

Study limitations

First, the study had the inherent limitations of a single-centre retrospective study, which could introduce potential selection bias and confounders. Second, the results must be interpreted with caution since the diameter of the ascending aorta was ≤ 50 mm and because patients with bicuspid aortic stenosis with AAD were excluded. However, patients with BAV are more prone to AAD, which could impact the balance of the two groups, and potential bias could exist. Third, we did not perform a propensity-score matching analysis due to the relatively small sample size, and the baseline characteristics were comparable between groups. Fourth, a potential limitation of the study is the significant difference between the patient group size of the non-AAD and AAD groups, which could potentially affect the mortality outcome statistics. Finally, device and prosthesis selection were not randomized but was at the operator’s discretion, and patient selection as well as the operator’s experience may have affected the clinical outcomes.

Conclusion

AAD does not appear to be associated with the procedural and mid-term clinical outcomes in patients undergoing TAVR.

Availability of data and materials

The data that support the findings of this study are available from the corresponding author upon reasonable request.

References

  1. Adams DH, Popma JJ, Reardon MJ, Yakubov SJ, Coselli JS, Deeb GM, et al. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med. 2014;370(19):1790–8.

    Article  CAS  Google Scholar 

  2. Popma JJ, Adams DH, Reardon MJ, Yakubov SJ, Kleiman NS, Heimansohn D, et al. Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery. J Am Coll Cardiol. 2014;63(19):1972–81.

    Article  Google Scholar 

  3. Nazer RI. Spiral aortoplasty for dilated ascending aorta: a new technique for high-risk patients with combined procedures. J Cardiothorac Surg. 2019;14(1):135.

    Article  Google Scholar 

  4. Kerneis C, Pasi N, Arangalage D, Nguyen V, Mathieu T, Verdonk C, et al. Ascending aorta dilatation rates in patients with tricuspid and bicuspid aortic stenosis: the COFRASA/GENERAC study. Eur Heart J Cardiovasc Imaging. 2018;19(7):792–9.

    Article  Google Scholar 

  5. Erbel R, Aboyans V, Boileau C, Bossone E, Bartolomeo RD, Eggebrecht H, et al. 2014 ESC Guidelines on the diagnosis and treatment of aortic diseases: document covering acute and chronic aortic diseases of the thoracic and abdominal aorta of the adult. The Task Force for the diagnosis and treatment of aortic Diseases of the European Society of Cardiology (ESC). Eur Heart J. 2014;35(41):2873–926.

    Article  Google Scholar 

  6. Hiratzka LF, Bakris GL, Beckman JA, Bersin RM, Carr VF, Casey DE Jr. A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery. ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the diagnosis and management of patients with thoracic aortic disease, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. J Am Coll Cardiol. 2010;55(14):e27–129.

    Article  Google Scholar 

  7. Rylski B, Szeto WY, Bavaria JE, Walsh E, Anwaruddin S, Desai ND, et al. Transcatheter aortic valve implantation in patients with ascending aortic dilatation: safety of the procedure and mid-term follow-up†. Eur J Cardiothorac Surg. 2014;46(2):228–33. discussion 33.

    Article  Google Scholar 

  8. Kassis N, Saad AM, Ahuja KR, Gad MM, Abdelfattah OM, Isogai T, et al. Impact of thoracic aortic aneurysm on outcomes of transcatheter aortic valve replacement: a nationwide cohort analysis. Catheter Cardiovasc Interv. 2021;97(3):549–53.

    Article  Google Scholar 

  9. Maeno Y, Yoon SH, Abramowitz Y, Watanabe Y, Jilaihawi H, Lin MS, et al. Effect of ascending aortic dimension on acute procedural success following self-expanding transcatheter aortic valve replacement: a multicenter retrospective analysis. Int J Cardiol. 2017;244:100–5.

    Article  Google Scholar 

  10. Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA. SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr. 2012;6(6):366–80.

    Article  Google Scholar 

  11. Liao YB, Zhao ZG, Wei X, Xu YN, Zuo ZL, Li YJ, et al. Transcatheter aortic valve implantation with the self-expandable venus A-Valve and CoreValve devices: preliminary Experiences in China. Catheter Cardiovasc Interv. 2017;89(S1):528–33.

    Article  Google Scholar 

  12. Wang R, Kawashima H, Gao C, Mou F, Li P, Zhang J, et al. Comparative quantitative Aortographic Assessment of Regurgitation in patients treated with VitaFlow Transcatheter Heart Valve vs. other Self-Expanding Systems. Front Cardiovasc Med. 2021;8:747174.

    Article  Google Scholar 

  13. Wang M, Song G, Chen M, Feng Y, Wang J, Liu X, et al. Twelve-month outcomes of the TaurusOne valve for transcatheter aortic valve implantation in patients with severe aortic stenosis. EuroIntervention. 2022;17(13):1070–6.

    Article  Google Scholar 

  14. Webb J, Gerosa G, Lefèvre T, Leipsic J, Spence M, Thomas M, et al. Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve. J Am Coll Cardiol. 2014;64(21):2235–43.

    Article  Google Scholar 

  15. Pibarot P, Ternacle J, Jaber WA, Salaun E, Dahou A, Asch FM, et al. Structural deterioration of Transcatheter Versus Surgical aortic valve bioprostheses in the PARTNER-2 trial. J Am Coll Cardiol. 2020;76(16):1830–43.

    Article  Google Scholar 

  16. Watanabe Y, Morice MC, Bouvier E, Leong T, Hayashida K, Lefèvre T, et al. Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Interv. 2013;6(9):955–64.

    Article  Google Scholar 

  17. Kim JB, Spotnitz M, Lindsay ME, MacGillivray TE, Isselbacher EM, Sundt TM. Risk of aortic dissection in the moderately dilated Ascending Aorta. J Am Coll Cardiol. 2016;68(11):1209–19. 3rd.

    Article  Google Scholar 

  18. Généreux P, Piazza N, Alu MC, Nazif T, Hahn RT, Pibarot P, et al. Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve Clinical Research. J Am Coll Cardiol. 2021;77(21):2717–46.

    Article  Google Scholar 

  19. Ancona MB, Moroni F, Chieffo A, Spangaro A, Federico F, Ferri LA, et al. Impact of ascending Aorta Dilation on Mid-Term Outcome after Transcatheter aortic valve implantation. J Invasive Cardiol. 2019;31(10):278–81.

    Google Scholar 

  20. Crawford MH, Roldan CA. Prevalence of aortic root dilatation and small aortic roots in valvular aortic stenosis. Am J Cardiol. 2001;87(11):1311–3.

    Article  CAS  Google Scholar 

  21. Benedik J, Pilarzcyk K, Wendt D, Price V, Tsagakis K, Perrey M, et al. Is there any difference in aortic wall quality between patients with aortic stenosis and those with regurgitation? Eur J Cardiothorac Surg. 2013;44(4):754–9.

    Article  Google Scholar 

  22. Son JY, Ko SM, Choi JW, Song MG, Hwang HK, Lee SJ, et al. Measurement of the ascending aorta diameter in patients with severe bicuspid and tricuspid aortic valve stenosis using dual-source computed tomography coronary angiography. Int J Cardiovasc Imaging. 2011;27(Suppl 1):61–71.

    Article  Google Scholar 

  23. Vallabhajosyula P, Gottret JP, Bavaria JE, Desai ND, Szeto WY. Endovascular repair of the ascending aorta in patients at high risk for open repair. J Thorac Cardiovasc Surg. 2015;149(2 Suppl):144–50.

    Article  Google Scholar 

  24. Girdauskas E, Disha K, Borger MA, Kuntze T. Long-term prognosis of ascending aortic aneurysm after aortic valve replacement for bicuspid versus tricuspid aortic valve stenosis. J Thorac Cardiovasc Surg. 2014;147(1):276–82.

    Article  Google Scholar 

  25. McKellar SH, Michelena HI, Li Z, Schaff HV, Sundt 3rd TM. Long-term risk of aortic events following aortic valve replacement in patients with bicuspid aortic valves. Am J Cardiol. 2010;106(11):1626–33.

    Article  Google Scholar 

  26. Ochiai T, Yoon SH, Sharma R, Miyasaka M, Maeno Y, Raschpichler M, et al. Prevalence and prognostic impact of ascending aortic dilatation in patients undergoing TAVR. JACC Cardiovasc Imaging. 2020;13(1 Pt 1):175–7.

    Article  Google Scholar 

  27. Abdel-Wahab M, Mehilli J, Frerker C, Neumann FJ, Kurz T, Tolg R, et al. Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial. JAMA. 2014;311(15):1503–14.

    Article  Google Scholar 

Download references

Acknowledgements

The authors would like to thank En Qiao for critically reviewing the manuscript.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

JY and WW wrote the main manuscript text and prepared all the figures and tables. Both authors reviewed the manuscript. Both authors read and approved the final manuscript.

Corresponding author

Correspondence to Wei Wang.

Ethics declarations

Ethical approval and consent to participate

The study protocol complied with the Declaration of Helsinki and was approved by the Medical Ethics Review Committee of Fuwai Hospital, and the requirement for informed consent was waived by the Medical Ethics Review Committee of Fuwai Hospital due to the nature of retrospective analyses.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yu, J., Wang, W. Short- to mid-term outcomes after transcatheter aortic valve replacement in patients with ascending aorta dilation: a single-centre retrospective analysis. BMC Cardiovasc Disord 23, 31 (2023). https://doi.org/10.1186/s12872-023-03063-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12872-023-03063-8

Keywords