Abstract

Background

The Sentinel cerebral embolic protection device (CEP) aims to reduce the risk of stroke during transcatheter aortic valve replacement (TAVR). We performed a systematic review and meta-analysis of propensity score matched (PSM) and randomized controlled trials (RCT) investigating the effect of the Sentinel CEP to prevent strokes during TAVR.

Methods

Eligible trials were searched through PubMed, ISI Web of science databases, Cochrane database, and proceedings of major congresses. Primary outcome was stroke. Secondary outcomes included all-cause mortality, major or life-threatening bleeding, major vascular complications and acute kidney injury at discharge. Fixed and random effect models were used to calculate the pooled risk ratio (RR) with 95% confidence intervals (CI) and absolute risk difference (ARD).

Results

A total of 4066 patients from 4 RCTs (3′506 patients) and 1 PSM study (560 patients) were included. Use of Sentinel CEP was successful in 92% of patients and was associated with a significantly lower risk of stroke (RR: 0.67, 95% CI: 0.48–0.95, p = 0.02. ARD: -1.3%, 95% CI: -2.3 – -0.2, p = 0.02, number needed to treat (NNT) = 77), and a reduced risk of disabling stroke (RR: 0.33, 95% CI: 0.17–0.65. ARD: -0.9%, 95% CI: -1.5 – -0.3, p = 0.004, NNT = 111). Use of Sentinel CEP was associated with a lower risk of major or life-threatening bleeding (RR: 0.37, 95% CI: 0.16–0.87, p = 0.02). Risk for nondisabling stroke (RR: 0.93, 95% CI: 0.62–1.40, p = 0.73), all-cause mortality (RR: 0.70, 95% CI: 0.35–1.40, p = 0.31), major vascular complications (RR: 0.74, 95% CI: 0.33–1.67, p = 0.47) and acute kidney injury (RR: 0.74, 95% CI: 0.37–1.50, p = 0.40) were similar.

Conclusions

The use of CEP during TAVR was associated with lower risks of any stroke and disabling stroke with an NNT of 77 and 111, respectively.

Peer Review reports

Introduction

If left untreated, aortic stenosis is associated with a high risk of morbidity and mortality [1, 2]. Transcatheter aortic valve replacement (TAVR) is an establishedtreatment for aortic stenosis and has been extensively investigated in randomized controlled trials (RCT) in the whole spectrum of surgical risk categories. TAVR has demonstrated excellent short- and mid-term safety and efficacy, compared to surgical aortic valve replacement (SAVR) [1,2,3,4,5,6,7]. However, overt stroke is still the most devastating complication of TAVR, occurring in 0.6 to 5% of patients during early follow-up [1,2,3,4,5,6,7]. Stroke is associated with high morbidity and mortality, and costs [8,9,10].

If TAVR is considered for use in younger patients with aortic stenosis and low surgical risk, the rate of stroke has to be minimised. Several cerebral embolic protection (CEP) devices have been developed. Some data from observational studies, randomized controlled trials and ultimately from meta-analysis suggest that the use of CEP devices in general was associated with a lower risk of stroke [11, 12]. Contrary, although CEP devices seem to reduce lesion volume during TAVR, this effect did not translate into a reduction in hard clinical outcomes as shown by another meta-analysis [13]

However, only the Sentinel CEP is approved by the FDA and readily available for cerebral protection during TAVR. The Sentinel CEP device is a dual-filter embolic protection device which is implemented percutaneously through a 6 French trans-arterial catheter prior to TAVR. The two embolic filters are placed: one in the brachiocephalic artery (proximal filter) and one in the left common carotid artery (distal filter). The filters are removed from the patient after completion of the intervention [14]. The recent PROTECTED TAVR trial randomized 3000 patients to TAVR either with or without the Sentinel CEP device. The rate of stroke after TAVR through 72 h, or at discharge, was numerically lower in patients treated with the CEP device. However, due to the low number of primary events and the low effect size, the trial was deemed underpowered. Therefore, the present meta-analysis reviews data from all available propensity score matched and randomised controlled trials using the Sentinel CEP device to further investigate its effect on stroke and other clinical outcomes in a larger cohort.

Methods

We performed a systematic review and study-level meta-analysis of propensity score matched (PSM) studies and RCTs that tested the efficacy of Sentinel CEP device during TAVR according to current recommendations of the Cochrane Handbook for Systematic Reviews and the Meta-analysis of Interventions [15] and in compliance with the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) statement in healthcare interventions [16]. The meta-analysis was registered in the Open-Science-Framework registry (OSF. May 18. osf.io/jw9bz).

Study design and endpoints

PSM studies and RCTs investigating the efficacy of the Sentinel CEP device during TAVR were included. All other studies reporting outcomes with this CEP device were excluded, in order to reduce the selection and confounding biases of those studies. Two groups were compared, defined by intraprocedural use or no use of the Sentinel CEP device. The pre-specified primary outcome was stroke (all-cause stroke, disabling stroke, nondisabling stroke). Secondary endpoints included all-cause and cardiovascular mortality, major vascular complications, major or life-threatening bleeding, acute kidney injury at discharge or if unavailable at 30 days. Outcomes were defined according to the Valve Academic Research Consortium – 2 (VARC-2) or Neurologic Academic Research Consortium (NeuroARC) definitions [17, 18]. All endpoints were estimated according to the intention-to-treat (ITT) principle.

Search strategy

PubMed, Cochrane Library, ISI Web of science databases, and TCTMD.org were searched for abstracts, papers, and conference reports published up to September 20, 2022. The references of the selected articles were checked for other relevant citations. There were no language restrictions. The following combination of key words and Medical Subject Heading (MeSH) terms were used: “cerebral embolic protection,” “Sentinel cerebral protection system,” “transcatheter aortic valve implantation,” and “transcatheter aortic valve replacement” (Online Table S1 details search strategy for PubMed). Two authors (M.W. and I.H.) independently identified appropriate articles. Disagreements regarding study selection were resolved by consensus by a third independent investigator (F.M.)

Data extraction

Pre-determined data elements were extracted from each trial and entered in a structured dataset, including: baseline characteristics, TAVR access site, type of THV, clinical outcome measures (stroke, all-cause mortality, major/life-threatening bleeding, major vascular complications, acute kidney injury), and device success (defined as the correct deployment and retrieval of the device).

Data synthesis and analysis

Pooled risk ratios and 95% confidence intervals (CI) for binary outcomes were calculated. As mostly rare events were encountered, the Mantel–Haenszel method, which can include single-zero and double-zero studies, was used to combine the results [19]. The decision between fixed effect or random effect model was based on the characteristics of the individual studies. As no relevant differences in comorbidities of enrolled patients or regarding procedure techniques were identified the fixed effect model was primarily used in our analysis [15]. Furthermore, heterogeneity among trials was estimated and displayed for each outcome using chi-square tests and quantified with I2 statistics. Heterogeneity was considered low for I2 < 25%, moderate for I2 < 75%, and high for I2 ≥ 75% [20]. Only for the endpoint of major vascular complications moderate heterogeneity was found, subsequently the random effect model was used for this endpoint. Publication bias for each outcome was estimated via visual inspection of the funnel plot. All analyses were conducted with the STATA statistical software package (Version 16.1, StataCorp, College Station, Texas, USA) and Review Manager (RevMan, Version 5.4, The Cochrane Collaboration, 2020).

Results

Included studies

A total of 5 studies with 4066 patients met our inclusion criteria: four randomized controlled trials (3′506 patients) and one propensity score matched study (560 patients), published between 2016–2022 (Fig. 1). Study characteristics are presented in Table 1. Overall risk of bias was deemed low in all 5 trials.

Fig. 1
figure 1

Study selection process. CEP, cerebral embolic protection. M-H. RCT, randomized controlled trial. PSM, propensity score matched. TAVR, transcatheter aortic valve replacement

Table 1 Study characteristics

Primary endpoint

Stroke

All 5 trials contributed to the analysis of stroke events, with 4066 patients included (Fig. 2, Panel A). Patients in the Sentinel CEP device group had a lower risk of stroke compared with the control group (2.7% vs. 3.7%. RR: 0.67, 95% CI: 0.48–0.95, p = 0.02, heterogeneity p = 0.48, I2 = 0%). Absolute risk difference (ARD) was -1.3% (95% CI: -2.3 – -0.2, p = 0.02, heterogeneity p = 0.29, I2 = 20%, number needed to treat (NNT) = 77).

Fig. 2
figure 2

Stroke in patients undergoing TAVR with versus without Sentinel CEP. Forest plots of individual and summarized risk ratios of all-cause stroke (A), disabling stoke (B), nondisabling stroke (C) according to the use of the Sentinel CEP device versus not during TAVR. CI, confidence interval. CLEAN-TAVI, Claret Embolic Protection and TAVI. CEP, cerebral embolic protection. M-H, Mantel–Haenszel. MISTRAL-C, MRI Investigation With Claret. TAVR, transcatheter aortic valve replacement

Disabling stroke

All 5 trials reported on the rate of disabling stroke events, with 4065 patients included in the analysis (Fig. 2, Panel B). Patients in the Sentinel CEP group had a lower risk of disabling stroke compared with the control group (0.5% vs. 1.6%. RR: 0.33, 95% CI: 0.17–0.65, p = 0.001, heterogeneity p = 0.55, I2 = 0%). ARD was -0.9% (95% CI: -1.5 – -0.3, p = 0.004, heterogeneity p = 0.24, I2 = 0%, NNT = 111).

Nondisabling stroke

All 5 trials contributed to the analysis of nondisabling stroke events, with 4066 patients included in the analysis (Fig. 2, Panel C). No difference in risk of nondisabling stroke was found between patients in the Sentinel CEP and control group (2.1% vs. 2.1%. RR: 0.93, 95% CI: 0.62–1.40, p = 0.73, heterogeneity p = 0.63, I2 = 0%).

Secondary endpoints

All-cause mortality

All 5 trials contributed to the analysis of all-cause mortality, with 4066 patients included (Fig. 3, Panel A). No significant difference in risk of death was found between patients in the Sentinel CEP and control group (0.7% vs. 0.9%. RR: 0.70, 95% CI: 0.35–1.40, p = 0.31, heterogeneity p = 0.26, I2 = 24%).

Fig. 3
figure 3

Secondary clinical outcomes in patients undergoing TAVR with versus without Sentinel CEP. Forest plots of individual and summarized risk ratios of all-cause mortality (A), major or life-threatening bleeding (B), major vascular complications (C) and acute kidney injury (D) according to the use of the Sentinel CEP device versus not during TAVR. CI, confidence interval. CLEAN-TAVI, Claret Embolic Protection and TAVI. CEP, cerebral embolic protection system. M-H, Mantel–Haenszel. MISTRAL-C, MRI Investigation With Claret. TAVR, transcatheter aortic valve replacement

Major or life-threatening bleeding

3 trials reported on the rate of major or life-threatening bleeding, with 725 patients included in the analysis (Fig. 3, Panel B). Patients in the Sentinel CEP group had a lower risk of major or life-threatening bleeding compared with the control group (1.9% vs. 5.5%. RR: 0.37, 95% CI: 0.16–0.87, p = 0.02, heterogeneity p = 0.76, I2 = 0%). ARD was -3% (95% CI: -6.0 – -1.0, p = 0.02, heterogeneity p = 0.27, I2 = 24%).

Major vascular complications

4 trials reported on the rate of major vascular complications, with 1088 patients included in the analysis (Fig. 3, Panel C). No significant difference in risk of major vascular complications was found between patients in the Sentinel CEP and control group (5.1% vs. 6.0%. RR: 0.74, 95% CI: 0.33–1.67, p = 0.47, heterogeneity p = 0.14, I2 = 45%, random effects model).

Acute kidney injury

All 5 trials contributed to the analysis of acute kidney injury, with 4066 patients included (Fig. 3, Panel D). No significant difference in risk of acute kidney injury was found between patients in the Sentinel CEP and control group (0.6% vs. 0.9%. RR: 0.74, 95% CI: 0.37–1.50, p = 0.40, heterogeneity p = 0.63, I2 = 0%).

Discussion

Our meta-analysis included all available propensity score-matched and randomized clinical trial data, with the use of the Sentinel CEP device in patients undergoing TAVR. The results suggest that use of the Sentinel CEP effected a significant reduction in the risk of all-cause and disabling stroke. The CEP device can be used in most patients (procedural success > 90%) with a good safety profile, i.e., no increase in the risk of major vascular complications or acute kidney injury.

Cerebrovascular events continue to be a major complication associated with TAVR during short-term [25] and long-term follow up [26]. As stroke after TAVR is a relevant predictor for morbidity and mortality [27], reducing the risk of stroke is an important goal, especially when considering patients who are relatively young and have low surgical risk profile. Interest in neuroprotection during TAVR has led to the development of several types of CEP devices in order to reduce thrombembolic events during valve implantation procedures [28]. The Sentinel CEP device is the only FDA approved system. Previous studies have consistently demonstrated that the Sentinel CEP device captures debris in up to 99% of patients [28]. Imaging studies showed that patients treated using the Sentinel CEP had fewer new brain lesions, lower total lesion volume [22], and reduced frequency of ischemic cerebral lesions in potentially protected areas [21] than patients treated without the device. Some data suggest that use of the Sentinel CEP device has the potential to preserve early neurocognitive performance after TAVR [22].

Debate on stroke

Recently, the large scale PROTECTED TAVR RCT reported data investigating the effect of the Sentinel CEP on the important endpoint of procedure-related stroke in patients undergoing TAVR [24]. The primary endpoint of stroke within 72 h after TAVR or before discharge did not significantly differ between the CEP and the control group (2.3% vs. 2.9%, p = 0.30). While the incidence of stroke in the CEP group was in the anticipated range, the number of events in the control group was lower than expected during the planning phase of the trial. The trial was statistically underpowered to detected such a small effect of the Sentinel CEP device. The low event rate in the control group is a good sign, as it demonstrates progress with the contemporary TAVR procedure in relation to strokes, even without the use of a CEP device. However, patients enrolled in the PROTECTED TAVR study had also a lower surgical risk than those in previous studies, potentially explaining the low stroke rate in the control group [14, 21,22,23]. Adding data from other studies our meta-analysis suggest a significant lower risk for all-cause stroke with the use of the Sentinel CEP device during TAVR (RR: 0.67, ARD -1.3%).

The incidence of disabling stroke is of outmost importance from the perspective of both patients and clinicians. Our meta-analysis suggests a significant lower risk of disabling stroke with the use of the Sentinel CEP compared to the control group (RR: 0.33, ARD -0.9%, NNT 111). This is in line with the PROTECT TAVR trial, which found a significantly lower rate of disabling stroke in the Sentinel CEP group compared to control group (0.5% vs. 1.3%) [24]. Based on these data, one additional disabling stroke could be prevented for every 125 patients treated with the Sentinel CEP device.

Interestingly, neither our meta-analysis, nor any single trial among those analyzed, found that use of the Sentinel CEP device was effective at preventing nondisabling strokes during TAVR. Reasons for this are not entirely clear, but the design of the Sentinel CEP device provides one possible explanation: The pore size of the filters (140 µm) blocks large, but not small emboli, potentially preventing larger disabling strokes, rather than smaller non-disabling strokes. However, the fact that blockage of small cerebral arteries can lead to clinical meaningful strokes, depending on the brain area does question the former theory. A clear answer why the CEP device does not influence non-diabaling strokes cannot be given from out analysis.

When should the Sentinel CEP device be used during TAVR?

Based on results of our meta-analysis, the Sentinel CEP device shows an excellent safety profile and potentially prevents periprocedural strokes. The number needed to treat to prevent one stroke according to our analysis is about 77 patients. Assuming a price per CEP device of about $2′000 would translate into expected total costs of about $154′000 to prevent one stroke. However, lifetime cost per person after stoke is with $103′576 also substantial [29]. In which population the use of Sentinel CEP device is cost-effective remains uncertain. It might be a valid strategy to use the CEP device in a younger TAVR population but refrain from using it in the very eldery (≥ 85–90 years of age).

Overall our results might encourage some operators to continue to use the Sentinel CEP device. If only the trial results from the recent large PROTECTED TAVR trial with the missed primary endpoint are considered, however, some physicians will refrain from using the CEP device to avoid adding relevant cost to the TAVR procedure without a proven clinical benefit. Furthermore, it is not entirely clear who might benefit from the use of CEP devices, as no direct link has been established between the amount of captured debris, anatomical/clinical factors, and the rate of stroke [27, 30, 31]. The recent PROTECTED TAVR trial failed to identify a subgroup of patients that might particularly benefit from the CEP device [24]. We recommend a careful discussion between physicians and patients regarding the use of the Sentinel CEP, incorporating the risks and benefits based on our meta-analysis and other data from recent randomized trials.

We are eagerly awaiting the large BHF PROTECT TAVI study, which will enroll 8000 patients and provide more conclusive information to the interventional community about the effectiveness of the Sentinel CEPS during TAVR. But we must be cautious. Assuming a similar rate of stroke for the awaited BHS PROTECT TAVI trial as seen in the recently published PROTECTED TAVR trial the BHS PROTECT TAVI trial might still fail to demonstrate a protective effect of the Sentinel CEP device. 22′084 patients would be required for an adequately powered study to give a 80% chance of detecting a significant reduction in stroke, assuming an incidence of 2.3% in the Sentinel CEP group vs. 2.9% in the control group as found in the PROTECTED TAVR trial [24].

Limitations

The number of available studies included in our meta-analysis was limited. Except for PROTECTED TAVR, the studies had small sample sizes, considering the very low event rate of the primary outcome. This meta-analysis used study level data, as we were unable to access patient-level data. The assessment of stroke varied among the trials, from just clinical assessment to thorough diagnostic workup by neurologists in conjunction with imaging studies. These circumstances might have led to under-detection or over-detection of events. Furthermore, the events were not always adjudicated by an independent clinical events committee.

Some studies did not report on the sites of bleeding, and therefore, the reason for lower bleeding events in cases using the Sentinel CEP remains unclear. Finally, data regarding other important outcomes, such as intra-procedural stroke, cost, length of hospital stay, re-admission, and longer-term outcomes were scarce in the individual trials and could not be incorporated in our meta-analysis. Sensitivity analysis considering only randomized controlled trials demonstrated a trend towards a lower rate of stroke with the use of the Sentinal CEP device [RR 0.76, (95% CI: 0.52, 1.09), I2 = 0%]. Incorporating propensity score-matched observational data might have overestimated the effect size of the CEP device.

Conclusion

Results of our meta-analysis of clinical trial data for patients undergoing TAVR suggest a significant reduction in the risk of stroke with the use of the Sentinel CEP device. The device can be used in most patients and has a good safety profile, showing no increase in the risk of major vascular complications or acute kidney injury. Larger randomized clinical trials are warranted to confirm these results. The large BHF PROTECT TAVI study should further define the effectiveness of the Sentinel CEP in preventing strokes during TAVR.

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Abbreviations

CEP:

Cerebral embolic protection

TAVR:

Transcatheter aortic valve replacement

THV:

Transcatheter heart valve

References

  1. Adams DH, Popma JJ, Reardon MJ, Yakubov SJ, Coselli JS, Deeb GM, Gleason TG, Buchbinder M, Hermiller J Jr, Kleiman NS, et al. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med. 2014;370(19):1790–8.

    Article  CAS  PubMed  Google Scholar 

  2. Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363(17):1597–607.

    Article  CAS  PubMed  Google Scholar 

  3. Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK, Thourani VH, Tuzcu EM, Miller DC, Herrmann HC, et al. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. 2016;374(17):1609–20.

    Article  CAS  PubMed  Google Scholar 

  4. Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK, Russo M, Kapadia SR, Malaisrie SC, Cohen DJ, Pibarot P, et al. Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients. N Engl J Med. 2019;380(18):1695–705.

    Article  PubMed  Google Scholar 

  5. Popma JJ, Deeb GM, Yakubov SJ, Mumtaz M, Gada H, O’Hair D, Bajwa T, Heiser JC, Merhi W, Kleiman NS, et al. Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients. N Engl J Med. 2019;380(18):1706–15.

    Article  PubMed  Google Scholar 

  6. Reardon MJ, Van Mieghem NM, Popma JJ, Kleiman NS, Sondergaard L, Mumtaz M, Adams DH, Deeb GM, Maini B, Gada H, et al. Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. 2017;376(14):1321–31.

    Article  PubMed  Google Scholar 

  7. Thyregod HG, Steinbruchel DA, Ihlemann N, Nissen H, Kjeldsen BJ, Petursson P, Chang Y, Franzen OW, Engstrom T, Clemmensen P, et al. Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis: 1-Year Results From the All-Comers NOTION Randomized Clinical Trial. J Am Coll Cardiol. 2015;65(20):2184–94.

    Article  PubMed  Google Scholar 

  8. Davlouros PA, Mplani VC, Koniari I, Tsigkas G, Hahalis G. Transcatheter aortic valve replacement and stroke: a comprehensive review. Journal of geriatric cardiology : JGC. 2018;15(1):95–104.

    CAS  PubMed  PubMed Central  Google Scholar 

  9. Nuis RJ, Van Mieghem NM, Schultz CJ, Moelker A, van der Boon RM, van Geuns RJ, van der Lugt A, Serruys PW, Rodes-Cabau J, van Domburg RT, et al. Frequency and causes of stroke during or after transcatheter aortic valve implantation. Am J Cardiol. 2012;109(11):1637–43.

    Article  PubMed  Google Scholar 

  10. Werner N, Zeymer U, Schneider S, Bauer T, Gerckens U, Linke A, Hamm C, Sievert H, Eggebrecht H, Zahn R. Incidence and Clinical Impact of Stroke Complicating Transcatheter Aortic Valve Implantation: Results From the German TAVI Registry. Catheter Cardiovasc Interv. 2016;88(4):644–53.

    Article  PubMed  Google Scholar 

  11. Baloch ZQ, Haider SJ, Siddiqui HF, Shaikh FN, Shah BUD, Ansari MM, Qintar M. Utility of Cerebral Embolic Protection Devices in Transcatheter Procedures: A Systematic Review and Meta-Analysis. Curr Probl Cardiol. 2023;48(7): 101675.

    Article  PubMed  Google Scholar 

  12. Shimamura J, Kuno T, Malik A, Yokoyama Y, Gupta R, Ahmad H, Briasoulis A. Safety and efficacy of cerebral embolic protection devices in patients undergoing transcatheter aortic valve replacement: a meta-analysis of in-hospital outcomes. Cardiovasc Interv Ther. 2022;37(3):549–57.

    Article  PubMed  Google Scholar 

  13. Bagur R, Solo K, Alghofaili S, Nombela-Franco L, Kwok CS, Hayman S, Siemieniuk RA, Foroutan F, Spencer FA, Vandvik PO, et al. Cerebral Embolic Protection Devices During Transcatheter Aortic Valve Implantation: Systematic Review and Meta-Analysis. Stroke. 2017;48(5):1306–15.

    Article  PubMed  Google Scholar 

  14. Kapadia SR, Kodali S, Makkar R, Mehran R, Lazar RM, Zivadinov R, Dwyer MG, Jilaihawi H, Virmani R, Anwaruddin S, et al. Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement. J Am Coll Cardiol. 2017;69(4):367–77.

    Article  PubMed  Google Scholar 

  15. Higgins J, Thomas J, Chandler J, Cumpston M, Page M. Welch Ve: Cochrane Handbook for Systematic Reviews of Interventions. 2nd ed. Chichester (UK): John Wiley & Sons; 2019.

    Book  Google Scholar 

  16. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP, Clarke M, Devereaux PJ, Kleijnen J, Moher D. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ. 2009;339: b2700.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Kappetein AP, Head SJ, Genereux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. Eur Heart J. 2012;33(19):2403–18.

    Article  PubMed  Google Scholar 

  18. Lansky AJ, Messe SR, Brickman AM, Dwyer M, van der Worp HB, Lazar RM, Pietras CG, Abrams KJ, McFadden E, Petersen NH, et al. Proposed Standardized Neurological Endpoints for Cardiovascular Clinical Trials: An Academic Research Consortium Initiative. J Am Coll Cardiol. 2017;69(6):679–91.

    Article  PubMed  Google Scholar 

  19. Bohning D, Mylona K, Kimber A. Meta-analysis of clinical trials with rare events. Biometrical journal Biometrische Zeitschrift. 2015;57(4):633–48.

    Article  PubMed  Google Scholar 

  20. Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003;327(7414):557–60.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Haussig S, Mangner N, Dwyer MG, Lehmkuhl L, Lucke C, Woitek F, Holzhey DM, Mohr FW, Gutberlet M, Zivadinov R, et al. Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis: The CLEAN-TAVI Randomized Clinical Trial. JAMA. 2016;316(6):592–601.

    Article  PubMed  Google Scholar 

  22. Van Mieghem NM, van Gils L, Ahmad H, van Kesteren F, van der Werf HW, Brueren G, Storm M, Lenzen M, Daemen J, van den Heuvel AF, et al. Filter-based cerebral embolic protection with transcatheter aortic valve implantation: the randomised MISTRAL-C trial. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2016;12(4):499–507.

    Article  PubMed  Google Scholar 

  23. Seeger J, Gonska B, Otto M, Rottbauer W, Wohrle J. Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement Significantly Reduces Death and Stroke Compared With Unprotected Procedures. JACC Cardiovasc Interv. 2017;10(22):2297–303.

    Article  PubMed  Google Scholar 

  24. Kapadia SR, Makkar R, Leon M, Abdel-Wahab M, Waggoner T, Massberg S, Rottbauer W, Horr S, Sondergaard L, Karha J, Gooley R, Satler L, Stoler RC, Messé SR, Baron SJ, Seeger J, Kodali S, Krishnaswamy A, Thourani VH, Harrington K, Pocock S, Modolo R, Allocco DJ, Meredith IT, Linke A. PROTECTED TAVR Investigators. Cerebral Embolic Protection during Transcatheter Aortic-Valve Replacement. N Engl J Med. 2022;387(14):1253-63.

  25. Siontis GCM, Overtchouk P, Cahill TJ, Modine T, Prendergast B, Praz F, Pilgrim T, Petrinic T, Nikolakopoulou A, Salanti G, et al. Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis. Eur Heart J. 2019;40(38):3143–53.

  26. Bjursten H, Norrving B, Ragnarsson S. Late stroke after transcatheter aortic valve replacement: a nationwide study. Sci Rep. 2021;11(1):9593.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  27. Vlastra W, Jimenez-Quevedo P, Tchetche D, Chandrasekhar J, de Brito FS, Jr., Barbanti M, Kornowski R, Latib A, D’Onofrio A, Ribichini F, et al. Predictors, Incidence, and Outcomes of Patients Undergoing Transfemoral Transcatheter Aortic Valve Implantation Complicated by Stroke. Circ Cardiovasc Interv. 2019;12(3): e007546.

    Article  PubMed  Google Scholar 

  28. Jobanputra Y, Jones BM, Mohananey D, Fatima B, Kandregula K, Kapadia SR. Cerebral protection devices for transcatheter aortic valve replacement. Expert Rev Med Devices. 2017;14(7):529–43.

    Article  CAS  PubMed  Google Scholar 

  29. Taylor TN, Davis PH, Torner JC, Holmes J, Meyer JW, Jacobson MF. Lifetime cost of stroke in the United States. Stroke. 1996;27(9):1459–66.

    Article  CAS  PubMed  Google Scholar 

  30. Van Mieghem NM, El Faquir N, Rahhab Z, Rodriguez-Olivares R, Wilschut J, Ouhlous M, Galema TW, Geleijnse ML, Kappetein AP, Schipper ME, et al. Incidence and predictors of debris embolizing to the brain during transcatheter aortic valve implantation. JACC Cardiovasc Interv. 2015;8(5):718–24.

    Article  PubMed  Google Scholar 

  31. Schmidt T, Akdag O, Wohlmuth P, Thielsen T, Schewel D, Schewel J, Alessandrini H, Kreidel F, Bader R, Romero M, Ladich E, Virmani R, Schäfer U, Kuck KH, Frerker C. Histological Findings and Predictors of Cerebral Debris From Transcatheter Aortic Valve Replacement: The ALSTER Experience. J Am Heart Assoc. 2016;5(11):e004399.

Download references

Acknowledgements

Not applicable

Disclosure

ST is a consultant and/or proctor for New Valve Technology / Biosensors, Boston Scientific, Abbott, Medtronic, Carag and Medira, has received institutional research grants from Boston Scientific and Fumedica and holds equity in Hi-D Imaging. MW is a proctor for New Valve Technology / Biosensors. The other authors have no conflicts of interest to declare.

Funding

No founding required.

Author information

Authors and Affiliations

Authors

Contributions

MW, FM and ST had the original idea for the study. The protocol was designed and refined by MW, IJH, RCBD. The literature search and data collection was performed by MW, IJH and FM. MW led the statistical analysis. All authors contributed to the interpretation of the data. MW and IJH wrote the initial draft of the manuscript. All authors contributed to this paper significantly and approved the final version of the manuscript.

Corresponding author

Correspondence to Mathias Wolfrum.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

ST is a consultant and/or proctor for New Valve Technology / Biosensors, Boston Scientific, Abbott, Medtronic, Carag and Medira, has received institutional research grants from Boston Scientific and Fumedica and holds equity in Hi-D Imaging. MW is a proctor for New Valve Technology / Biosensors. The other authors have no conflicts of interest to declare.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wolfrum, M., Handerer, I.J., Moccetti, F. et al. Cerebral embolic protection during transcatheter aortic valve replacement: a systematic review and meta-analysis of propensity score matched and randomized controlled trials using the Sentinel cerebral embolic protection device. BMC Cardiovasc Disord 23, 306 (2023). https://doi.org/10.1186/s12872-023-03338-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12872-023-03338-0

Keywords