- Case report
- Open access
- Published:
Atrial-His bundle pacing in fulminant myocarditis with ventricular arrhythmia: a case report
BMC Cardiovascular Disorders volume 22, Article number: 497 (2022)
Abstract
Background
Fulminant myocarditis is a clinical syndrome associated with threatening dysrhythmia which temporary pacemaker can be used for life-saving support. As a method of physiological pacing, His bundle pacing (HBP) maintain better cardiac synchronization than traditional right ventricular (RV) pacing.
Case presentation
It’s a severe case of fulminant myocarditis in a 41-year-old patient who presented for recurrent arrhythmias with hemodynamic instability. Temporary His bundle pacing combined with optimal medical therapy and extracorporeal membrane oxygenators (ECMO) supported him through his critical period of hospitalization.
Conclusions
During 1-year follow up, the cardiac function recovery was obvious without any pacing related complications. Echocardiography showed better atrioventricular and intra-ventricular synchronization during HBP in DDD mode. This is the first reported case of temporary His-purkinje conduction system pacing used for severe fulminant myocarditis.
Background
Fulminant myocarditis is a clinical syndrome with severe symptoms of acute heart failure, cardiogenic shock, or life-threating rhythm disturbances which should be treated with full supportive care, using aggressive pharmacologic therapy and mechanical circulatory support [1]. His-purkinje conduction system pacing as a physiologic pacing method can achieve cardiac resynchronization which is similar to native conduction. We report a unique case of severe fulminant myocarditis with recurrent malignant ventricular arrhythmias, complete heart block and hemodynamic instability. Atrial-His bundle pacing supported the patient hemodynamics through this critical period of his hospitalization.
Case presentation
A 41-year-old previously healthy male presented to our hospital after a week of fever. He had dyspnea and hypotension. He had no long-term medication. He did not smoke cigarettes, take alcohol or illicit drugs. Hypoxic on presentation, he required supplemental oxygen via nasal cannula. Heart rhythm was irregular but he did not have any murmur. Laboratory data on admission showed an alanine aminotransferase (ALT) level of 3904 U/L, creatine kinase (CK) level of 2463 U/L, creatine kinase-MB (CK-MB) level of 193 U/L, troponin I (cTnI) level of 42.38 ug/l, brain natriuretic peptide level of 734 pg/ml, and serum creatinine level of 111umol/l. The laboratory test of herpesvirus IgM antibody showed positive and the result of metagenome and target gene sequencing was negative. Chest radiograph showed obvious pulmonary congestion (Fig. 1 B4). Twelve lead electrocardiogram (ECG) during hospitalization demonstrated ventricular tachycardia (Fig. 1 A1) and sinus arrest with ventricular escape rhythm (Fig. 1 A2). Intra-cardiac electrogram recorded on pacemaker programmer showed atrial pacing at 60 bpm resulted Wenckebach phenomenon of atrioventricular conduction (Fig. 1 B3). Coronary angiography revealed no coronary artery stenosis and left ventriculography showed diffuse hypokinesis. Left ventricular ejection fraction (LVEF) by echocardiography demonstrated mean ejection fraction of 25%.
Diagnosis of fulminant myocarditis might have different underlying causes and pathogenetic processes-viral, bacterial, toxic, and autoreactive. Histological and immune-histological specimens made from the biopsies help diagnosis in the clinical course. However, in this case heart failure and severe arrhythmias dominated the clinical manifestations which made myocardial biopsy impossible. Eventually, from the history, clinical examination and electrocardiogram, fulminant myocarditis associated with cardiogenic shock was our primary diagnosis. Initially, norepinephrine, dobutamine, milrinone and other positive inotropic drugs and vasoactive agents were used to maintain his vital signs. However, cardiogenic shock and arrhythmias could not be corrected, then ECMO was used in hospital day 11. Despite the contemporary use of ECMO for three weeks, cardiogenic shock persisted with conduction disease, associated with recurrent monomorphic ventricular tachycardia, requiring sequential atrioventricular pacing support (Fig. 1 A). Due to the concern of cardiac dys-synchronization caused by conventional temporary RV pacing, we performed HBP to prevent further deterioration of cardiogenic shock and the inability to wean him off mechanical circulatory support. Conventional two-chamber pacemaker was selected for temporary pacing device. A lead delivery system consisting of C315 His catheter (Medtronic Inc., Minneapolis, MN, USA) and Select Secure 3830 pacing lead (Medtronic Inc., Minneapolis, MN) was placed at the septal area of the atrioventricular junction. In that region endocardial mapping was performed using the lead tip until a clear His bundle potential was obtained with HV interval of 59 ms (Fig. 1 B2). At this level, pacing at variable amplitudes showed nonselective His bundle capture with important narrowing of the paced QRS complex. Selective HBP was achieved at 1.25 V/0.5 ms with R wave of 3.6mv and bipolar impedance of 430Ω. HBP at 140 bpm resulted in 1:1 HV conduction. Besides, in addition to sinus arrest, the patient also had problems with atrioventricular conduction, therefore a dual chamber DDD pacing mode was programmed to preserve atrioventricular activation as part of the most physiological conduction rather than single chamber AAI or VVI pacing mode. The total procedural time was 53 min, and no procedural-related complication was noted in a fully anticoagulated state with heparin due to the presence of ECMO.
Postoperative pacing rate was adjusted to 80-100 bpm, with invasive hemodynamic monitoring by arterial line and right cardiac catheterization demonstrating optimal pulmonary arterial pressure (PAP), cardiac output (CO), cardiac index (CI), central venous pressure (CVP) and invasive arterial pressure (IAP) (Table 1). The pacing parameters were stable. Remarkably, his ventricular tachycardia ceased within 24 h of HBP. ECMO was decannulated 8 days after pacemaker implantation. Considering the lack of sinoatrial node and atrioventricular node recovery two weeks after temporary HBP, permanent pacemaker was implanted using the same venous access. We selected HBP combined with back-up right ventricular septal pacing (RVSP) to prevent the increase of His capture threshold and useless of His electrode due to the progression of conduction disease to distal position. During his follow-up at 1 year, selective His bundle captured threshold and non-selective His bundle captured threshold at 1-year follow-up were 0.5 V/0.5 ms and 1.5 V/0.5 ms, respectively. Echocardiography reported a remarkable improvement of LVEF to 58%, along with optimal heart failure medical therapy (Table 1). 12-lead ECG showed sinus arrest and atrioventricular block with the Wenckebach block point of AV conduction maintained at 60 bpm.
The cardiac mechanical synchrony was separately evaluated by transthoracic echocardiography (TTE) in three different pacing modes with HBP in DDD mode, RVSP in DDD mode and HBP in VVI mode at 1-year follow-up, with a washout period of 5 min between each pacing mode. In terms of left ventricular function, HBP with DDD mode showed better left ventricular (LV) synchrony evaluated by tissue Doppler imaging (TDI) and LV systolic function reflected by LVEF and CO than RVSP. RV systolic function with HBP evaluated by tricuspid annular plane systolic excursion (TAPSE) was better than that of RVSP. Finally, the intraventricular mechanical delay (IVMD) which was defined as the difference between the LV pre-ejection period (aortic pre-ejection time, APEI) and RV pre-ejection period (pulmonary pre-ejection time, PPEI) was used to evaluate mechanical delay between the left and right ventricle, showed a significant difference between HBP and RVSP. RVSP had a worse IVMD compared to HBP. In addition, DDD pacing mode showed optimum atrioventricular synchronization with better morphology of mitral peak early diastolic velocity (E’), mitral peak late diastolic velocity (A’) and mitral E/A ratio (Fig. 2).
Discussion and conclusions
Fulminant myocarditis is a clinical syndrome characterized by severe myocardial inflammation frequently associated with threatening dysrhythmia manifested as bradycardia, conduction block, ventricular tachycardia and ventricular fibrillation. ECMO use is commonly required for fulminant myocarditis patients with hemodynamic instability to support them through the acute phase of cardiogenic shock [2, 3]. Conduction system injury involving sinoatrial node and atrioventricular junction was persistent in this patient which mainly manifested with uncorrectable sinus arrest and AVB requiring temporary pacing as a mean for chronotropic support [4]. However, traditional RV endocardial pacing in the setting of cardiogenic shock may lead to further deterioration of hemodynamics due to worsening LV function. Therefore, two 3830 active-fixation leads were selectively fixed in the low septum of right atrium and His bundle position with DDD pacing mode of atrial-Hisian-ventricular sequential conduction to achieve the precise and entire atrioventricular and intra-ventricular synchronization. Consequently, with the use of the most physiological pacing mode and ECMO, this patient had the most optimal clinical outcomes through temporary conduction system activation and mechanical circulatory support for hemodynamic collapse.
The effectiveness [5, 6] and safety [7,8,9] of conduction system pacing have been confirmed, however there are no report of conduction system pacing used for temporary pacing for fulminant myocarditis. This case illustrates an alternate approach that in patients with fulminant myocarditis, especially those with conduction disease and heart failure, His purkinje conduction system pacing with DDD mode may be preferable to conventional temporary right ventricular apical pacing which maintains the better atrial-Hisian-ventricular synchronization. Finally, clinical studies in experienced centers in the future can provide more evidence for this approach.
Patient Perspective
“My heart failure symptoms resolved after optimal medical therapy and pacemaker implantation. My functional capacity returned to baseline at 1 year follow up. I’m tremendously grateful to the conduction system pacing team at the First affiliated hospital of Wenzhou university.” The patient talked about it at 1-year follow-up.
Availability of data and materials
All the data supporting our findings are contained within the manuscript.
Abbreviations
- HBP:
-
His bundle pacing
- RV:
-
Right ventricular
- ECMO:
-
Extracorporeal membrane oxygenators
- ALT:
-
Alanine aminotransferase
- CK:
-
Creatine kinase
- CK-MB:
-
Creatine kinase-MB
- cTnI:
-
Troponin I
- AVB:
-
Atrioventricular block
- LVEF:
-
Left ventricular ejection fraction
- PAP:
-
Pulmonary arterial pressure
- CO:
-
Cardiac output
- CI:
-
Cardiac index
- CVP:
-
Central venous pressure
- IAP:
-
Invasive arterial pressure
- RVSP:
-
Right ventricular septal pacing
- TTE:
-
Transthoracic echocardiography
- LV:
-
Left ventricular
- TDI:
-
Tissue Doppler imaging
- TAPSE:
-
Tricuspid annular plane systolic excursion
- IVMD:
-
Intraventricular mechanical delay
- APEI:
-
Aortic pre-ejection time
- PPEI:
-
Pulmonary pre-ejection time
- E’:
-
Mitral peak early diastolic velocity
- A’:
-
Mitral peak late diastolic velocity
References
Ginsberg F, Parrillo J. Fulminant myocarditis. Crit Care Clin. 2013;2(3):465–83.
Kim I, Yang H, Kim W, et al. Pathological substratum for a case of fulminant myocarditis treated with extracorporeal membrane oxygenation and subsequent heart transplantation. J Korean Med Sci. 2015;10(9):1367–72.
Liu D, Xu J, Yu X. Successful treatment of fulminant myocarditis in an adult in emergency department: A case report. Medicine (Baltimore). 2019;98(49):e18292.
Adachi Y, Kinoshita O, Hatano M, et al. Successful bridge to recovery in fulminant myocarditis using a biventricular assist device: a case report. J Med Case Reports. 2017;5(1):295.
Su L, Wu S, Wang S, et al. Pacing parameters and success rates of permanent His-bundle pacing in patients with narrow QRS: a single-centre experience. Europace. 2019;21(5):763–70.
Su L, Wang S, Wu S, et al. Long-Term Safety and Feasibility of Left Bundle Branch Pacing in a Large Single-Center Study. Circ Arrhythm Electrophysiol. 2021;14(2):e009261.
Su L, Xu T, Cai M, et al. Electrophysiological characteristics and clinical values of left bundle branch current of injury in left bundle branch pacing. J Cardiovasc Electrophysiol. 2020;31(4):834–42.
Upadhyay GA, Cherian T, Shatz DY, et al. Intracardiac Delineation of Septal Conduction in Left Bundle-Branch Block Patterns. Circ. 2019;139(16):1876–88.
Beer D, Subzposh FA, Colburn S, et al. His bundle pacing capture threshold stability during long-term follow-up and correlation with lead slack. Europace. 2021;23(5):757–66.
Acknowledgements
Not applicable.
Funding
This work was supported by Key Research and Development Program of Zhejiang (grant number 2019C03012).The funding body played no roles in the design of the study and collection, analysis, and interpretation of data and in writing the manuscript.
Author information
Authors and Affiliations
Contributions
HWJ and SL designed the study. JLM drafted the manuscript. WLG and XL participated in the measurement of echocardiography. FXF, HX, ZX, WSJ and ZCH participated in the entire treatment process. RC participated in the manuscript revision process. All authors have read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
Written informed consent was obtained from the patient for publication of this case report and any accompanying images. There is a copy of the consent form is available for the Editor to review upon request.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Jiang, L., Wang, L., Zhao, C. et al. Atrial-His bundle pacing in fulminant myocarditis with ventricular arrhythmia: a case report. BMC Cardiovasc Disord 22, 497 (2022). https://doi.org/10.1186/s12872-022-02936-8
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12872-022-02936-8