Skip to main content

Study protocol: MyoFit46—the cardiac sub-study of the MRC National Survey of Health and Development

Abstract

Background

The life course accumulation of overt and subclinical myocardial dysfunction contributes to older age mortality, frailty, disability and loss of independence. The Medical Research Council National Survey of Health and Development (NSHD) is the world’s longest running continued surveillance birth cohort providing a unique opportunity to understand life course determinants of myocardial dysfunction as part of MyoFit46–the cardiac sub-study of the NSHD.

Methods

We aim to recruit 550 NSHD participants of approximately 75 years+ to undertake high-density surface electrocardiographic imaging (ECGI) and stress perfusion cardiovascular magnetic resonance (CMR). Through comprehensive myocardial tissue characterization and 4-dimensional flow we hope to better understand the burden of clinical and subclinical cardiovascular disease. Supercomputers will be used to combine the multi-scale ECGI and CMR datasets per participant. Rarely available, prospectively collected whole-of-life data on exposures, traditional risk factors and multimorbidity will be studied to identify risk trajectories, critical change periods, mediators and cumulative impacts on the myocardium.

Discussion

By combining well curated, prospectively acquired longitudinal data of the NSHD with novel CMR–ECGI data and sharing these results and associated pipelines with the CMR community, MyoFit46 seeks to transform our understanding of how early, mid and later-life risk factor trajectories interact to determine the state of cardiovascular health in older age.

Trial registration: Prospectively registered on ClinicalTrials.gov with trial ID: 19/LO/1774 Multimorbidity Life-Course Approach to Myocardial Health- A Cardiac Sub-Study of the MCRC National Survey of Health and Development (NSHD).

Peer Review reports

Background

Unprecedented numbers of people are now surviving into older age [1, 2] which means that the global trends for cardiovascular disease (CVD) prevalence will continue to increase, further adding to the burden of disease [3]. Improving our understanding of the causes of CVD is crucial to developing lifestyle or pharmacological interventions that can either prevent or delay the onset of disease.

The progressive structural, functional and hemodynamic changes affecting the myocardium as a result of ageing, lead to mortality, morbidity, disability and loss of independence in later life [4, 5]. Risk factors for cardiometabolic disease impact the heart from early childhood [6, 7] and with advancing age, the health of the myocardium is progressively compromised by overt stepwise and subclinical cumulative injury [5]. It is currently unclear how the age-dependent influences of multimorbidity, or the effect of early-life exposures, influence the various pathophysiological processes that lead to cardiac disease [8]. Prospectively collected data across the whole life course are required to address these research questions.

The Medical Research Council (MRC) National Survey of Health and Development (NSHD) is the longest running continuous study of human development in the world, which started as an English, Scottish and Welsh representative sample of 5,362 participants, born in one week in 1946 [9,10,11,12]. Repeated data collection waves since birth have provided detailed information on early-life exposures, traditional cardiometabolic risk factors and emergent multimorbidity [9, 11]. With members now aged ≥ 75, it is an opportune time to perform advanced cardiac phenotyping to understand which life course trajectories are conducive to the preservation of cardiovascular longevity. We propose to combine high spatial and temporal resolution electrocardiographic imaging (ECGI) and cardiovascular magnetic resonance (CMR) techniques to study the structure, function, electrophysiology (EP) and hemodynamics of the whole heart and correlate this information with the rich life course data that the NSHD cohort provides.

We describe here the research protocol of ‘MyoFit46’, a prospective longitudinal sub-study of 550 NSHD study members which is set to run for a total of 5 years. We summarize the study’s organization, funding, design, participant inclusion criteria, data sharing policy and analysis strategy.

Methods

Study organization

This prospective longitudinal NSHD sub-study will take place at the University College London (UCL) Bloomsbury Centre for Clinical Phenotyping in central London. MyoFit46 is funded by the British Heart Foundation (BHF) special project grant (to G.C. SP/20/2/34841) and supported by the MRC (MC UU 00019/1).

Separate ethical approval for the main NSHD study has been provided by Research Ethics Committees (REC) in England and Scotland as outlined in previous papers [9, 10, 13]. Ethical approval for this study was granted by the London Queen Square REC (REC: 19/LO/1774. London REC—Queen Square, IRAS: 254776). All participants will provide written informed consent to participate in the study and for their study data to be stored electronically in accordance with the Data Protection Act (2018) as laid out by the legal requirements of the General Data Protection Regulation (GDPR).

Participants

Entry criteria to the study are based on maximizing the life course data available for analysis. We will recruit 550 NSHD participants, some of which have been recruited to other recent sub-studies [12] and who have not previously withdrawn, died, or remained untraced from the main study by age 70. Participants will have a rich life course data set available having participated in the majority of data collection sweeps (Table 1). The NSHD is a representative sample of 5362 males and females born in the UK in March 1946 originally intended to answer questions on fertility rates and obstetric servives [14]. At the 2014–2016 NSHD data sweep we obtained data on surviving study members that lived in Britain and with whom we still had contact [14], which has provided us with 2502 participants potentially available to invite for examination. The first 550 study members fulfilling these criteria and providing written consent will be included. Excluded individuals will be those with contraindications to contrast perfusion CMR, including but not limited to those with permanent implantable cardiac electronic devices, claustrophobia, renal failure, severe asthma or known trifascicular or higher degree conduction block on their resting surface 12-lead ECG.

Table 1 Summary of the various data collection sweeps so far undertaken on NSHD cohort participants over time

Study outline

All participants meeting the inclusion criteria will be invited to take part through an invitation letter and following verbal agreement, a suitable date/time for the CMR scan will be booked and transport arranged to and from the study center. In light of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) global pandemic specific measures will be implemented to minimize the risk of participant/investigator infection or transmission throughout the study period in accordance with changing government guidelines. A flowchart outlining the study protocol is shown in Fig. 1.

Fig. 1
figure 1

MyoFit46 study flowchart. BP, Blood pressure; CMR, cardiac magnetic resonance imaging; ECG, electrocardiogram; GP, general practitioner; MRI, magnetic resonance imaging; REDCap, research electronic data capture; PACS, picture archiving and communication system

Assessment and management of risk

A duty-of-care protocol based on the NSHD protocol used previously, in accordance with the MRC/Wellcome Trust guidelines [15] will be implemented for the purposes of feeding back health-related findings from the study. All baseline measurements will be routinely reported to the general practitioner with a copy also being sent to the participant.

All CMR images will be pre-reported by a cardiology clinical research fellow and finalized by a consultant cardiologist. Any extra-cardiac findings considered to be clinically significant will be secondarily reported by a consultant radiologist at University College London National Health Service (NHS) Foundation Trust. The study follows guidelines based on the UK Biobank imaging study [16] and CMR information is only reported back to the GP in the case that an abnormality is considered medically actionable. A non-exhaustive list of potential CMR findings considered reportable are summarized in Table 2.

Table 2 Overview of clinically significant reportable CMR findings

All serious unexpected study-related adverse events will be reported immediately according to standard operating procedures for research studies carried out at UCL.

Data handling and management

All data will be handled in accordance with the UK DPA 2018 as laid out by the UK GDPR. All clinical data will be pseudonymized by tokenization and will not bear the participant’s name or other directly identifiable data. The participant’s study identification number only, will be used for identification. All participant information including pre-screening questionnaires, relevant medical history, anthropometric measurements, baseline ECG and CMR data points will be imported into the secure research electronic data capture project (REDCap V.7.3.2) controlled by the principal investigator and accessible to named research assistants.

Study protocol description

Blood and urine specimen collection and storage

Blood samples will be collected and stored for future biomarker analysis. Two 4.0 ml ethylenediaminetetraacetic acid and two clotted 3.5 ml serum-separating tube whole blood samples will be collected. All tubes will be spun at 1300 g for 20 min at room temperature to generate supernatant (plasma), buffy coat and red blood cells which will be individually aliquoted into 1 ml, polypropylene, cryovials and stored at – 80 °C, for later analysis. One 10.5 ml PAXgene DNA tube and one 9.4 ml PAXgene RNA tube will be collected and stored upright for 24 h at – 20 °C, and then transferred to – 80 °C, for future analysis. Point-of-care testing will be carried out for creatinine using the StatSensor Xpress Creatinine monitor (Nova Biomedical, USA) and hemoglobin using HemoCue Hb 801 monitor (HemoCue AB, Sweden) that also permits derivation of hematocrit. A random urine sample will be collected by the participant in a polypropylene universal container and aliquoted into slender conical tubes for storage at – 80 °C.

Baseline measurements

Height and weight will be measured according to standardized protocols previously described [12]. Bioimpedance body composition measurements (TANITA Cooperation, Japan) will also be recorded. Lying, sitting and 3-min standing blood pressure (BP) will be measured (OMROM MIT ELITE PLUS; OMRON Healthcare UK Ltd. Milton Keynes) on the left arm over 3 acquisitions. A resting 12-lead surface ECG will be recorded using a PC based ECG monitor (Cardioperfect Workstation; Welch Allyn, New York. USA). Resting heart rate (HR) variability will be assessed immediately after the standard ECG using the same lead positions for a total of 5 min.

Electrocardiographic imaging (ECGI)

ECGI is the process of combining heart and torso geometry with multiple body surface potentials to generate epicardial electrograms and panoramic maps of cardiac excitation [17,18,19]. ECGI has been extensively validated in ex vivo animal studies using a torso-tank experimental method [20, 21] and in vivo animal experiments. It has also been shown to accurately correlate with invasive EP mapping in ventricular tachycardia (VT) [22], it has been validated when applied to cardiac computed tomography [23] and using a multi-electrode ECGI sock intraoperatively [24]. ECGI has also been successfully combined, by our group, with CMR in patients amyloidosis [25] and arrhythmogenic cardiomyopathy [26]. It is with this method that we can detect subtle EP abnormalities that are often missed by conventional 12-lead ECG [27]. The challenge for the cardiologist is identifying whether subtle EP abnormalities, which are more prevalent in the ageing myocardium, will put an individual at higher risk of sudden cardiac death or not [28]. In order to bridge this knowledge gap, ECGI will allow us to link regional EP aberrations with myocardial substrate changes for mechanistic insights into the aetiology of arrythmias. Our pipeline will enable reconstruction of epicardial surface biopotentials projected onto the cardiac geometry using inverse solution mathematics to measure epicardial activation and repolarization parameters which can then be spatially correlated with myocardial tissue characteristics derived by CMR. [29].

We recently developed a re-usable and dry-electrode-based CMR-compatible vest to permit high-throughput ECGI research and seamless integration with CMR (up to 3 Tesla [T]). This was achieved in collaboration with textile engineers at the École Nationale Supérieure des Arts et Industries Textiles (ENSAIT, Roubaix, France) and with g.Tec medical engineering GmbH (Schiedlberg, Austria). The technology consists of two matching wash-resilient and reusable garments: one embedded with 256 dry electrodes (the electrode vest) and the other (the CMR-safe marker vest) embedded with co-registered fiducial markers (Beekley medical, Bristol, Connecticut). The signal from each electrode is collected and amplified using the HIamp 256 bundle GT-8016/USBamp GT-0216 and processed for analysis in specially designed software, g.Recorder (g.Tec).

Prior to CMR, the participant will wear the electrode vest which is secured onto the chest using adjustable fasteners. Body surface potentials will be measured from all electrodes at a sampling frequency of 2400 Hz for 5 min at rest, in the supine position. The electrode vest is then removed leaving only the marker vest which the participant wears inside the CMR scanner. Accurate electro-anatomical mapping of ECGI and CMR data will then be achieved through an initial 4 mm contiguous-slice transaxial black-blood thoracic stack for marker co-registration. Our ECGI workflow is summarized in Fig. 2.

Fig. 2
figure 2

High-throughput reusable ECGI vest for CMR. A The garment is embedded with 256 uniformly distributed dry electrodes that connect to g.HIamp for the recordings. B To ensure good skin contact of the dry electrodes an inflatable gilet is worn over the electrode vest for the duration of the recordings. This design allows for rapid montage onto and off the chest. After the recording is complete the inflatable jacket and electrode vest are removed leaving only the marker vest that the participant then wears into the CMR scanner. ECGI, electrocardiographic imaging. Other abbreviations as in Fig. 1

CMR

Outline

Imaging will be performed on a 3 T [200 × 80mT/m/s x mT/m] MRI system (Magnetom Prisma, Serial Number 166032, Siemens, 60 cm bore) operating VE11C-SP01, with an 18-channel phased-array chest coil and spine array (up to 24-elements) equipped with Gadgetron [30] (Linux box, 24 cores). Participants will be scanned using a protocol which combines standard and advanced CMR imaging techniques and is designed to be completed within a 45 min scanning session. Standardized CMR protocols have been described in detail previously [31, 32]. Brachial and non-invasive central BP assessment using a Cardioscope II BP + device (USCOM, Sydney, Australia; cuff on the right arm) will be performed at baseline in the scanner bore, prior to the scan starting, followed by resting, peak stress (during adenosine administration) and recovery measurements, also inside the scanner bore. Continuous digital pulse oximeter monitoring will be obtained throughout using the Nonin 7500FO fiber optic MRI table-top pulse oximeter (Nonin, Plymouth, USA). The CMR protocol is outlined in Fig. 3 and MR sequence details summarized in Table 3.

Fig. 3
figure 3

MyoFit46 CMR protocol. 2/3/4CH, 2/3/4 chamber; 4D, 4-dimensional; Ao, aorta; AVLAX, aortic valve long axis; AVSAX, aortic valve short axis; ECV, extracellular volume; HASTE, half-fourier single-shot turbo spin-echo; LGE, late gadolinium enhancement; LVLAX, left ventricular long axis; LVSAX, left ventricular short axis

Table 3 MyoFit46 CMR sequence parameters

Cardiac structure and function

Initial CMR scout imaging will include sagittal, coronal and transverse piloting of the chest in single heartbeat, free-breathing, acquisitions. This will be followed by a thin contiguously sliced transaxial set of turbo spin echo (TSE) images (4 mm thickness no gap) across the chest (approximately 90 slices) using a half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence. These T2 weighted, dark blood, images will localize the fiducial markers on the ECGI vest and facilitate co-registration during post processing. Local 2nd order cardiac shimming will be prescribed onto HASTE data and automatically copied to the rest of our protocolled sequences. To assess left ventricular (LV) structure and function we will acquire three long axis cines (vertical long axis, horizontal long axis and left ventricular outflow tract) and an LV short axis cine stack (SAX) using breath-held ECG retro-gated balanced steady state free precession (bSSFP) imaging. To assess right ventricular (RV) structure and function we will acquire RV outflow tract (sagittal and oblique-sagittal planes) and vertical RV long-axis bSSFP cines. For more detailed aortic valve (AV) assessment we will acquire coronal LV outflow tract (LVOT) and AV short axis bSSFP cines.

Tissue characterization

The native myocardial T1 time, before the administration of gadolinium based contrast agent (GBCA), can lengthen even in the absence of late gadolinium enhancement (LGE) and it is this ability to detect so-called ‘subclinical’ fibrosis that will make it particularly useful for our analysis of myocardial resilience in old age [33, 34]. In order to obtain native T1 maps we will acquire breath-held single shot bSSFP motion-corrected (MOCO) modified Look-Locker inversion recovery (MOLLI) images using prototype 5 s(3 s)3 s, at the basal, mid and apical LVSAX levels, with volume selective magnetic field strength (B0) shimming, in diastole [35, 36]. Standard deviation (SD) maps will be automatically generated and used to cross check the reliability of corresponding MOLLI T1 values in co-registered regions of interest, aiming for a SD of < 40 ms. A description of this technique has been outlined elsewhere [37].

To create extracellular volume (ECV) maps we will perform two co-registered T1 mapping acquisitions: before and approximately 10 min after infusion of the second dose of GBCA (Dotarem, Gadoterate meglumine, Guerbet, France) using MOLLI prototypes 5 s(3 s)3 s) and 4 s(1 s)3 s(1 s)2 s respectively, at the basal, mid and apical LVSAX slice. We will then generate pixel-wise ECV maps by determining the ratio of the change in T1 values, following correction for blood cell density (using validated point-of-care hematocrit readings) [31, 38, 39]. This will be done by transposing regions of interest (ROIs) in the septal midwall (or alternative remote myocardial zone) and blood pool from native onto the post-GBCA T1 maps. Two types of ECV maps will be generated per participant for cross-validation: (1) A synthetic ECV map, which will be generated directly from the scanner using a synthetic hematocrit derived from native T1 values, as described previously [39]; (2) A conventional ECV map, which will be generated at the end of each scan using the measured blood hematocrit (derived from the hemoglobin value obtained from point of care testing).

We will perform single-slice breath-held T2 mapping using a MOCO single shot bSSFP sequence at the level of the mid LV short axis and prior to GBCA administration.

Aortic flow imaging

With advancing age, biochemical, histological and blood flow changes in the main arteries result in wall stiffening [40]. Arterial stiffness has traditionally been measured in peripheral vessels due to ease of access, even though aortic stiffness is a stronger prognostic marker because of its resultant increase in LV afterload and wider downstream end-organ damage [41]. To analyze the effects of aortic stiffening in older age we will measure local aortic distensibility (derived from aortic area measurements) and regional pulse wave velocity (PWV) across the ascending aorta and aortic arch. Both regional and local measurements of aortic stiffness capture variation in aortic tissue composition across its course, but have different sensitivities to pathology related to arterial stiffening and are associated with different cardiovascular outcomes [42]. In order to obtain measurements of aortic length, we will initially acquire an ECG-gated, free-breathing sagittal cine of the aorta (‘candy cane’ view). This image will then serve as a localizer to pilot blood-flow velocity maps at the level of the bifurcation of the main pulmonary artery transecting the ascending and descending thoracic aorta. We will use a high temporal resolution phase-contrast free-breathing ECG-gated gradient echo sequence as previously described [31, 32, 43] (imaging parameters provided in Table 3). Aortic flow imaging will be performed at baseline and repeated during peak stress (immediately before the stress perfusion acquisition) alongside simultaneous pressure waveform and pulse oximetry measurements. An outline of the methods used to derive pulse wave velocity is summarized in Fig. 4. Measurements of flow velocity and pressure waveforms will be used to derive wave intensity, wave separation, reservoir pressure and reflection magnitude as previously described [44].

Fig. 4
figure 4

Measuring aortic pulse wave velocity (PWV). A Free breathing gradient echo phase contrast cine of the ascending aorta at the level of the pulmonary artery bifurcation. B Aortic ‘candy cane’ used to pilot the aortic flow. Points 4 and 12 are highlighted to show the linear plane used for transection and for measuring 3D distance using our dedicated software. C Flow wave curves of both the ascending and descending aorta after normalization for peak flow which are used to measure the transit time. D PWV (m/s) is then calculated as 3D distance divided by transit time. 3D, 3-dimensional; PWV, pulse wave velocity

Stress perfusion imaging

For myocardial ischemia evaluation we will perform stress perfusion imaging using adenosine on all participants using a dual-cannula approach (typically sited in the antecubital fossae) which has been previously described [45]. Intravenous adenosine will be infused peripherally at 140 µg/kg/min from one of the cannulas for a minimum of 3 min and a maximum of 4 min to achieve an adequate response (assessed through a HR increment of 10 beats per minute and/or the development of symptoms). A higher dose of 175 µg/kg/min may be infused for a further 2 min in the event of limited symptoms or failure to increment HR by a minimum of 10 beats per minute. The first dose of Dotarem (0.05 mmol/kg) will be injected via the other canula at a rate of 4 mL/second along with 20 mL of saline. The adenosine infusion will be stopped during the first pass perfusion image acquisition which will be acquired using a free-breathing MOCO saturation-recovery bSSFP sequence to cover 3 LVSAX slices across every heartbeat. Approximately 10 min following peak stress, rest perfusion imaging (using the same sequences described above) will then be completed without adenosine, using the second dose of Dotarem.

Late gadolinium enhancement

To assess the presence of LGE we will acquire an LVSAX stack of conventional (‘bright-blood’) LGE images using a free-breathing MOCO bSSFP sequence with phase-sensitive inversion-recovery (PSIR) [46]. LGE acquisitions will commence approximately 5 min after the second dose of Dotarem.

4-Dimensional flow

Four-dimensional (4-D) intracavitary flow CMR provides comprehensive hemodynamic flow assessments, taking into account the multidirectional and multidimensional nature of blood flow through the cardiac chambers [47] with the potential to improve our understanding of the ageing cardiovascular phenotype. We will compare the use of respiratory-navigated vs. free-breathing retrospectively ECG-gated, spoiled gradient echo sequences (work-in-progress CS785B, Siemens Healthineers, Erlangen, Germany), with field of view covering the LVOT, proximal aorta, and all 4 cardiac chambers. The acquisition will be performed at the end of the CMR protocol with GBCA on board to allow for improved blood myocardial contrast. Sequence parameters based on the published literature [48] are provided in Table 3.

Quality assurance

Normal values for key CMR biomarkers collected in MyoFit46 will be generated from healthy volunteer datasets acquired using the same sequences on the same magnet system. The upper and lower range of normal values will be defined as the mean ± 1.96 standard deviations from the normal data, according to standardized recommendations [38].

Prior to commencing native myocardial T1 mapping in MyoFit46, two quality assurance steps will be implemented.

A quality assurance phantom testing protocol for T1, T2 and ECV mapping will be undertaken to verify the stability of our magnet-sequence combination over time and throughout the project lifecycle. We will use the medical-device grade T1 mapping and ECV standardization (T1MES) phantom [49] (field-strength specific for 3 T with regulatory clearance from the Food and Drug Administration and Conformité Européene-marking) as well as the T2 Phantom [50] (field-strength agnostic). Both devices have been previously developed by our group in collaboration with Resonance Health (Perth, Australia) and with the US and German National Metrology Institutes (National Institute of Standards and Technology and Physikalisch-Technische Bundesantalt respectively) [49, 51]. At study start and study close both phantoms (stored in the temperature-controlled MRI scanner environment) will be interrogated by flip angle maps and be scanned using slow overnight inversion recovery spin echo (IRSE) and multi-echo SE, to establish reference T1 and T2 values. At study start, study close and once every 2 months between these timepoints, the T1 MES phantom will additionally be scanned in accordance with the T1MES user manual [51, 52] using the fat/water sequence for field maps and using 3 repeats of the MOLLI 5 s(3 s)3 s and 4 s(1 s)3 s(1 s)2 s prototypes. At study start, study close and once every 2 months between these timepoints, the T2 phantom will additionally be scanned using the fat/water sequence and three repeats of the T2 mapping sequence. Phantom body temperature will be recorded prior to the start of each scan session, aiming for an ambient CMR room temperature of 21–22 °C. A schematic of our phantom-based quality assurance framework for MyoFit46 is presented in Fig. 5.

Fig. 5
figure 5

T1 and T2 Phantom QA framework. The same imaging protocol (defined here) is used for QA of multi-parametric T1 and T2 mapping data during the project lifecycle. Sequences in black are performed at baseline and then repeated every 8 weeks. Sequences in grey are performed at baseline and then for a total of 2 per year. 3D, 3-dimensional; FA, flip angle; IRSE, inversion recovery spin echo; MOLLI, modified Look-Locker inversion recovery; QA, quality assurance; SSFP, steady-state free precession

Imaging pipelines and analyses

Primary imaging analyses

Imaging pipelines

All CMR image DICOMs (Digital Imaging and Communications in Medicine), derived results and associated ROIs will be stored on a customized web-based server running XNAT 1.6.5 and hosted at UCL. DICOM-compliant imaging format will be used for all MRI data including raw list mode data and images that have been reconstructed on the scanner using the Gadgetron framework. CMR data will be analyzed using Circle Cardiovascular Imaging, cvi [42] version 5.3.2 (Calgary, Canada).

CMR analysis

Standardized CMR image interpretation and post-processing will be performed as previously described [31, 32, 53, 54]. Briefly, analyses will include volumetric measurements of the 4 cardiac chambers (using manual epicardial and endocardial contour tracings), assessment of biventricular and valvular function, analysis of native myocardial T1 and T2, stress perfusion imaging and LGE assessment. Papillary muscles and trabecular tissue will be consistently included in the LV mass measurements, as previously described [53, 54]. Left ventricular volumetric and maximal wall thickness analyses will additionally be performed using the previously validated openCARE artificial intelligence (AI) analysis platform. This platform has already been shown to have improved precision when compared to human observers in independent studies [55].

A standard operating procedure has been developed for the manual analysis of LGE, T1, T2 and ECV by trained researchers. For T1, T2 and ECV analysis, epicardial and endocardial contours will be drawn manually with 10% erosion from the blood myocardial boundary and divided according to the 16-segment American Heart Association (AHA) model. On the native and post-GBCA MOLLI T1 maps, a ROI will be drawn in the mid septum and co-registered with automatically generated pixel-wise SD maps. Semiautomated LGE quantification will be carried out using a 2 SD and a 5 SD approach following manual selection of an ROI in an area of remote/dark myocardium [36, 56]. We will also use the full width half maximum technique [57] for comparison against the other methods. Segments with LGE will be annotated to allow for subsequent interpretation of the mapping data [54].

Aortic flow analysis

Proximal ascending and descending thoracic aortic contours will be traced semi-automatically using validated software (ArtFun, INSERM U678, Paris, France) to derive flow-velocity waveforms [43, 58]. Aortic distensibility will be measured at local, specified regions of the aorta and calculated according to established methods [43, 59]. PWV over the upper thoracic aorta will be measured using length and transit time (from derived aortic velocity profiles) [43].

4-Dimensional flow analysis

Intracavitary 4-D flow CMR will allow us to derive parameters such as turbulent kinetic energy, wall shear stress, PWV and variations in LV vortices [47, 60]. For example, previous studies have shown that there is an inverse relationship between LV diastolic vortices [61] and ageing and that turbulent kinetic energy could be a promising subclinical marker of LV dysfunction [62]. 4-D flow CMR also allows for detailed valve quantification with particularly promising results in mitral regurgitation, since it allows for direct quantification of flow at the level of the valve which remains valid even in the presence of other valvular lesions or shunts [63]. These markers of intracavitary hemodynamics will be used to characterize pathophysiological responses to ageing beyond conventional methods of flow. 4-D flow image post-processing will be performed using CAAS (PIE Medical Imaging, Maastricht, The Netherlands). During analysis we will ensure that any contours drawn in the magnitude images are cross-referenced with velocity images to take into account large movements and the effects of partial volume. Velocity data will be encoded into individual vectors, allowing us to assess local patterns of flow such as vortices, visualize and quantify wall shear stress and study kinetic energy [64].

ECGI analysis

Body surface ECGs collected by g.Recorder will be stored and analyzed offline using previously established methods [18, 25, 26]. Signal averaging will be performed using in-house, customized, software (Matlab, MathWorks, Natick, MA) to enhance the quality of the signals from body surface potentials. The location of the fiducial markers on the torso corresponding to the electrode positions will be combined with the heart-torso geometry obtained from the CMR HASTE stack and reconstructed to create epicardial meshes using commercially available software (Amira, ThermoFisher, MA, USA, version 2020.3). Unipolar epicardial electrograms will then be reconstructed by solving the inverse problem in collaboration with the Rudy laboratory [19, 26]. Generated epicardial maps will enable calculation of epicardial activation and repolarization times and corresponding isochrone maps will be generated for visualization. These maps will be used to identify discrete areas of abnormal electrophysiology and correlated with matching substrate abnormalities detected by CMR. An exemplar pilot isochrone map that we have created using this CMR-ECGI pipeline is reproduced in Fig. 6. At scale validation of the co-registration process with CMR has not been performed before and in order to address this we will carry out test–retest reproducibility and intra-/inter-observer variability studies. All raw and post-processed ECGI data will be stored securely in the project-specific UCL XNAT repository.

Fig. 6
figure 6

ECGI analysis workflow. A ECGI data is collected by g.Recorder software. B CMR image showing one transverse slice of the HASTE used to segment the epicardium. Note the fiducial MRI markers (white) situated on the anterior and posterior torso. C Ventricular segmentation of the same participant’s HASTE data, showing heart torso geometry and markers (Beekley medical, Bristol, Connecticut) following volume rendering, landmark localization and segmentation in Amira software (ThermoFisher, MA, USA, version 2020.3). D Signal averaging is performed using in house, customized software (Matlab, MathWorks, Natick, MA) and unipolar electrograms are then combined with Amira software heart torso geometry by solving the inverse problem of ECGI in collaboration with the Rudi laboratory. E Activation time isochrone maps in disease highlighting an area of fractionation corresponding to an area of LGE/scar in the mid anteroseptum of the left ventricle. EGM, electrogram. Other abbreviations as in Figs. 1, 2 and 3

Cardiac computational modelling

In order to extend our multi-dimensional deep phenotyping of the ageing heart we will perform advanced cardiac computational modelling in collaboration with the Barcelona Supercomputing center (Barcelona, Spain). Using the established ‘Alya Red’ [65] supercomputer driven data modelling protocol [65,66,67], we will combine epicardial electrophysiological data (from ECGI) with the rich myocardial structural, functional, perfusion and flow data obtained from CMR to create personalized electro-mechanical-flow whole-heart simulations per participant [68].

Study analysis Plan

Statistical analysis

Both overt and subclinical cardiovascular disease biomarkers (binary or continuous variables, such as LV ejection fraction, native T1, ECV, LGE, etc.) will be determined through this proposed CMR-ECGI deep phenotyping protocol and such biomarkers will serve as either outcome or predictor variables in the various analyses planned. On the one hand, MyoFit46 will unravel how key exposures during early-, mid- and later life (e.g. environmental pollution, communicable disease exposure, socioeconomic status, etc.) interact with traditional cardiovascular risk factors (e.g. smoking, obesity, alcohol intake, etc.) and multimorbidity to determine cardiovascular disease (outcome) in older age. On the other hand, we will also prospectively study the association between discovered cardiovascular disease biomarkers (predictors) and key outcomes of interest ascertained during long-term follow-up of the birth cohort participants (e.g. functional status or major adverse cardiovascular events such as hospital admissions, nonfatal stroke, myocardial infarction, cardiovascular death, etc.).

Since several of our exposures of interest are either categorical or represent trajectories/time-varying exposures; associations between exposures and outcomes will be analyzed using a range of statistical approaches relevant for life course data [69,70,71]. Associations between trajectories of exposures and cardiovascular disease biomarkers will be analyzed using latent growth curve analysis [71]. In order to subsequently link with outcomes we will use a two-step process as previously described [72]. We will use structural equation models using full information maximum likelihood to account for missing data in NSHD under missing at random assumptions.

Sample size estimates have been calculated to permit detection of a small effect size (Cohen’s f2 = 0.03) using multivariable regression analysis. A sample size of 533 achieves 80% power to detect an f2 ≥ 0.030 attributable to up to 9 independent variable(s) using an F-Test with a significance level (alpha) of 0.050. For categorical outcomes a logistic regression of a binary response variable on a continuous, normally distributed variable with a sample size of 533 observations achieves 92% power at a 0.05 significance level to detect a change corresponding to an odds ratio of 1.5.

Data sharing

A data sharing policy will be published and managed through MRC Slylark website (https://skylark.ucl.ac.uk/Skylark) including access to research publications, talks presented at international conferences and links to academic social media accounts. Raw data will be archived for a minimum of 10 years within the UCL open XNAT server (https://ucl-open-xnat.cs.ucl.ac.uk/app/template/Login.vm#!) and these data will be shared with bona fide researchers along with the relevant clinical and demographic metadata that will be archived in REDCap. CMR and ECGI standard operating procedures will be electronically archived alongside the data, and as hard copies. Software pipelines will be stored in electronic lab books, including software version numbers.

Discussion

MyoFit46 aims to combine the rich life course data of the NSHD with cutting-edge CMR and ECGI technologies and multi-dimensional cardiac simulations to provide new insights into the long-term myocardial sequelae of key exposures from birth. Uniquely the NSHD provides us with detailed, prospectively collected data since birth, allowing us to study the individual, combined and cumulative impacts of risk factors, and their mediators on myocardial health by older age. Previous older age cohorts have carried out CMR imaging, but none have performed CMR-ECGI integration with stress perfusion, multi-parametric mapping, and 4-D intracardiac flow as is being proposed here. ECGI will enable us to correlate overt and subclinical markers of arrhythmogenesis with CMR-derived structural and functional abnormalities. By merging these complex structural, functional, hemodynamic and electrophysiological data into cardiac computational models we be deepening our understanding of the ageing myocardium, representing a world first in terms of CMR-driven personalized care. We expect our results to impact public health by identifying novel risk factors for cardiovascular disease and addressing the growing challenge of multi-morbidity with the aim of maintaining myocardial health into older age for the benefit of humanity globally.

Availability of data and materials

Not applicable.

Abbreviations

AHA:

American Heart Association

AI:

Artificial intelligence

AV:

Aortic valve

BHF:

British Heart Foundation

BP:

Blood pressure

bSSFP:

Balanced steady state free precession

CMR:

Cardiovascular magnetic resonance

COVID-19:

Coronavirus disease 2019

CVD:

Cardiovascular disease

DICOM:

Digital Imaging and Communications in Medicine

DPA:

Data protection act

ECG:

Electrocardiogram

ECGI:

Electrocardiographic imaging

ECV:

Extracellular volume

EP:

Electrophysiology

FSE:

Fast spin echo

4-D:

Four-dimensional

GBCA:

Gadolinium based contrast agent

GDPR:

General Data Protection Regulation

HASTE:

Half Fourier acquisition single shot turbo spin echo

HR:

Heart rate

IRSE:

Inversion recovery spin echo

LGE:

Late gadolinium enhancement

LV:

Left ventricle

LVOT:

Left ventricular outflow tract

MOCO:

Motion corrected

MOLLI:

Modified look locker inversion recovery

MRC:

Medical Research Council

MRI:

Magnetic resonance imaging

NHS:

National Health Service

NSHD:

National Survey of Health and Development

PSIR:

Phase-sensitive inversion-recovery

PWV:

Pulse wave velocity

REC:

Research Ethics Committee

REDCap:

Research electronic data capture project

ROIs:

Regions of interest

RV:

Right ventricle

SARS-CoV-2:

Severe acute respiratory distress coronavirus 2

SAX:

Short axis stack

SD:

Standard deviation

T:

Tesla

TSE:

Turbo spin echo

UCL:

University College London

VT:

Ventricular tachycardia

References

  1. Roth GA, Mensah GA, Johnson CO, et al. Global burden of cardiovascular diseases and risk factors, 1990–2019: update from the GBD 2019 study. J Am Coll Cardiol. 2020;76(25):2982–3021.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Timmis A, Townsend N, Gale CP, et al. European society of cardiology: cardiovascular disease statistics 2019. Eur Heart J. 2020;41(1):12–85.

    Article  PubMed  Google Scholar 

  3. Abbafati C, Machado DB, Cislaghi B, et al. Global burden of 369 diseases and injuries in 204 countries and territories, 1990–2019: a systematic analysis for the Global Burden of Disease Study 2019. Lancet. 2020;396(10258):1204–22.

    Article  Google Scholar 

  4. Dai DF, Chen T, Johnson SC, Szeto H, Rabinovitch PS. Cardiac aging: from molecular mechanisms to significance in human health and disease. Antioxidants Redox Signal. 2012;16(12):1492–536.

    Article  CAS  Google Scholar 

  5. Pugh KG, Wei JY. Clinical implications of physiological changes in the aging heart. Drugs Aging. 2001;18(4):263–76.

    Article  CAS  PubMed  Google Scholar 

  6. Oyama K, El-Nachef D, Maclellan WR. Regeneration potential of adult cardiac myocytes. Cell Res. 2013;23(8):978–9.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  7. Bergmann O, Zdunek S, Felker A, et al. Dynamics of cell generation and turnover in the human heart. Cell. 2015;161(7):1566–75.

    Article  CAS  PubMed  Google Scholar 

  8. Topriceanu C-C, Moon JC, Hardy R, Chaturvedi N, Hughes AD, Captur G. Longitudinal birth cohort study finds that life-course frailty associates with later-life heart size and function. Sci Rep. 2021;11(1):1–10.

    Article  Google Scholar 

  9. Kuh D, Pierce M, Adams J, et al. Cohort profile: updating the cohort profile for the MRC National Survey of Health and Development: a new clinic-based data collection for ageing research. Int J Epidemiol. 2011;40(1):e1–9.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Kuh D, Wong A, Shah I, et al. The MRC National Survey of Health and Development reaches age 70: maintaining participation at older ages in a birth cohort study. Eur J Epidemiol. 2016;31(11):1135–47.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Wadsworth M, Kuh D, Richards M, Hardy R. Cohort profile: the 1946 National Birth Cohort (MRC National Survey of Health and Development). Int J Epidemiol. 2006;35(1):49–54.

    Article  PubMed  Google Scholar 

  12. Lane CA, Parker TD, Cash DM, et al. Study protocol: insight 46—a neuroscience sub-study of the MRC National Survey of Health and Development. BMC Neurol. 2017;17(1):1–25.

    Article  Google Scholar 

  13. Hardy R, Ghosh AK, Deanfield J, Kuh D, Hughes AD. Birthweight, childhood growth and left ventricular structure at age 60–64 years in a British birth cohort study. Int J Epidemiol. 2016;45(4):1091–102.

    PubMed  PubMed Central  Google Scholar 

  14. Kuh D, Wong A, Shah I, et al. The MRC National Survey of Health and Development reaches age 70: maintaining participation at older ages in a birth cohort study. Eur J Epidemiol. 2016;31(11):1135.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Medical Researcg Cuncil, The Wellcome Trust. Framework on the feedback of health-related findings in reseach 2014. Accessed February 27, 2021. Available from: https://mrc.ukri.org/documents/pdf/mrc-wellcome-trust-framework-on-the-feedback-of-health-related-findings-in-researchpdf/

  16. Gibson LM, Paul L, Chappell FM, et al. Potentially serious incidental findings on brain and body magnetic resonance imaging of apparently asymptomatic adults: systematic review and meta-analysis. BMJ. 2018;363:4577.

    Article  Google Scholar 

  17. Rudy Y, Burnes JE. Noninvasive electrocardiographic imaging. Ann Noninvasive Electrocardiol. 1999;4(3):340.

    Article  Google Scholar 

  18. Ramanathan C, Ghanem RN, Jia P, et al. Noninvasive electrocardiograpchic imaging for cardiac electrophysiology and arrythmia. Nat Med. 2004;10(4):42.

    Article  Google Scholar 

  19. Rudy Y. Non invasice ECG imaging (ECGI): mapping the arrythmic substrate of the human heart. Int J Cardiol. 2017;237:14.

    Article  Google Scholar 

  20. Oster HS, Taccardi B, Lux RL, et al. Non invasive electrocardiographic imaging. Circulation. 1997;96(3):1012.

    Article  CAS  PubMed  Google Scholar 

  21. Oster HS, Taccardi B, Lux RL, et al. Electrocardiographic imaging noninvasive characterization of intramural activation from inverse-reconstructed epicardial potential and electrograms. Circulation. 1998;97(15):1496.

    Article  CAS  PubMed  Google Scholar 

  22. Wang Y, Cuculich PS, Zhang J, et al. Non invasivee electroanatomic mapping of human ventricular arrythmias with electrocardiogtaphic imaging (ECGI). Sci Transl Med. 2011;3(98):98ra84.

    Article  PubMed  PubMed Central  Google Scholar 

  23. Cluitans MJM, Bonizzi P, Karel JMH, et al. In vivo validation of electrocardiographic imaging. JACC: Clin Electrophysiol. 2017;3(3):232.

    Google Scholar 

  24. Ghanem RN, Jia P, Ramanathan C, et al. Noninvasive electrocardiographic imaging (ECGI): comparison to intraoperative mapping in patients. Heart Ryhtm. 2005;2(4):339.

    Google Scholar 

  25. Orini M, Graham AJ, Martinez-Nagarro A, et al. Noninvasice mapping of the electrophysiological substrate in cardiac amalyoidosis and its relationship to structural abnormalities. J Am Heart Assoc. 2019;8(18):e012097.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Andrews CM, Srinivasan NT, Rosmini S, et al. Electrical and structural substrate of arrythmogenic right ventricular cardiomyopathy determined using noninvasive electrocardiographic imaging and late gadolinium magnetic resonance imaging. Circ Arrythm Electrophysiol. 2017;10(7):e005105.

    Article  Google Scholar 

  27. Sienieqicz Mbchb BJ, Tom I. Optimization of CRT programming using non invasice electrocardiographic imaging to assess the acute electrical effects of multipoint pacing CRT, electrocardiographci mapping, multi-point pacing, multi-site pacing, non responders. J Arrythm. 2019;35(2):267.

    Article  Google Scholar 

  28. Pathak RK, Sanders P, Deo R. Primary prevention implantable cardioverter-defibrillator and oppurtunities for sudden cardiac death risk assesment in non-ischaemic cardiomyopathy. Eur Heart J. 2018;39(31):2859.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  29. Graham AJ, Orini M, Zacur E, et al. Simultaneous comparison of electrocardiographic imaging and epicardial contact mapping in structural heart disease. Circ Arrhythmia Electrophysiol. 2019;12:e007120.

    Article  Google Scholar 

  30. Hansen MS, Sorensen TS. Gadgetron: an open source framework for medical image reconstruction. Magn Reson Med. 2013;69(6):1768–76.

    Article  PubMed  Google Scholar 

  31. Kramer CM, Barkhausen J, Bucciarelli-Ducci C, Flamm SD, Kim RJ, Nagel E. Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update. J Cardiovasc Magn Reson. 2020;22(1):1–8.

    Article  Google Scholar 

  32. Petersen SE, Matthews PM, Francis JM, et al. UK Biobank’s cardiovascular magnetic resonance protocol. J Cardiovasc Magn Reson. 2016;18(1):8.

    Article  PubMed  PubMed Central  Google Scholar 

  33. Dass S, Suttie JJ, Piechnik SK, et al. Myocardial tissue characterization using magnetic resonance noncontrast T1 mapping in hypertrophic and dilated cardiomyopathy. Circ Cardiovasc Imaging. 2012;5(6):726–33.

    Article  PubMed  Google Scholar 

  34. Ho CY, Abbasi SA, Neilan TG, et al. T1 measurements identify extracellular volume expansion in hypertrophic cardiomyopathy sarcomere mutation carriers with and without left ventricular hypertrophy. Circ Cardiovasc Imaging. 2013;6(3):415–22.

    Article  PubMed  PubMed Central  Google Scholar 

  35. Messroghli DR, Radjenovic A, Kozerke S, Higgins DM, Sivananthan MU, Ridgway JP. Modified look-locker inversion recovery (MOLLI) for high-resolution T 1 mapping of the heart. Magn Reson Med. 2004;52(1):141–6.

    Article  PubMed  Google Scholar 

  36. Messroghli DR, Moon JC, Ferreira VM, et al. Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2 and extracellular volume: a consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI). J Cardiovasc Magn Reson. 2017;19(1):75.

    Article  PubMed  PubMed Central  Google Scholar 

  37. Kellman P, Arai AE, Xue H. T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precision. J Cardiovasc Magn Reson. 2013;15(1):56.

    Article  PubMed  PubMed Central  Google Scholar 

  38. Messroghli DR, Moon JC, Ferreira VM, et al. Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2 and extracellular volume: A consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI). J Cardiovasc Magn Reson. 2017;19(1):1–24.

    Article  Google Scholar 

  39. Treibel TA, Fontana M, Maestrini V, et al. Automatic measurement of the myocardial interstitium synthetic extracellular volume quantification without hematocrit sampling. JACC Cardiovasc Imaging. 2016;9(1):54–63.

    Article  PubMed  Google Scholar 

  40. Mitchell GF, Hwang SJ, Vasan RS, et al. Arterial stiffness and cardiovascular events: the framingham heart study. Circulation. 2010;121(4):505–11.

    Article  PubMed  PubMed Central  Google Scholar 

  41. Mitchell G, van Buchem M, Sigurdsson S, et al. Arterial stiffness, pressure and flow pulsatility and brain structure and function: the Age. Gene/Environ Susceptibility-Reykjavik study Brain. 2011;134:13398–407.

    Google Scholar 

  42. McEneiry CM, Hall YIR, Qasem A, et al. Normal vascular aging: differential effects on wave reflection and aortic pulse wave velocity: the Anglo-Cardiff Collaborative Trial (ACCT). J Am Coll Cardiol. 2005;46(9):1753–60.

    Article  Google Scholar 

  43. Bhuva AN, D’Silva A, Torlasco C, et al. Training for a first-time marathon reverses age-related aortic stiffening. J Am Coll Cardiol. 2020;75(1):60–71.

    Article  PubMed  Google Scholar 

  44. Bhuca AN, D’Silva A, Torisco C, et al. Non-invasive assessment of ventriculo-arterial coupling using aortic wave intensity analysis combining central blood pressure and phase-contrast cardiovascular magnetic resonance. Eur Hear J Cardiovasc Imaging. 2020;21(7):805–13.

    Article  Google Scholar 

  45. Kellman P, Hansen MS, Nielles-Vallespin S, et al. Myocardial perfusion cardiovascular magnetic rsonance: optimized dual sequence and reconstruction for quantification. J Cardiovasc Magn Reson. 2017;19(1):1–14.

    Article  Google Scholar 

  46. Kellman P, Arai AE, McVeigh ER, Aletras AH. Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement. Magn Reson Med. 2002;47(2):372.

    Article  PubMed  PubMed Central  Google Scholar 

  47. Dyverfeldt P, Bissell M, Barker AJ, et al. 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson. 2015;17(1):72.

    Article  PubMed  PubMed Central  Google Scholar 

  48. François CJ, Srinivasan S, Schiebler ML, et al. 4D cardiovascular magnetic resonance velocity mapping of alterations of right heart flow patterns and main pulmonary artery hemodynamics in tetralogy of Fallot. J Cardiovasc Magn Reson. 2012;14(1):16.

    Article  PubMed  PubMed Central  Google Scholar 

  49. Captur G, Gatehouse P, Keenan KE, et al. A medical device-grade T1 and ECV phantom for global T1 mapping quality assurance - the T1 Mapping and ECV standardization in cardiovascular magnetic resonance (T1MES) program. J Cardiovasc Magn Reson. 2016;18(1):1–20.

    Article  Google Scholar 

  50. Seo HS, Captur G, Ittermann B, et al. 27A medical device grade T2 phantom to quality control inflammation imaging by CMR. Eur Hear J Cardiovasc Imaging. 2019;20(2):jez111-005.

    Article  Google Scholar 

  51. Captur G, Bhandari A, Brühl R, et al. T 1 mapping performance and measurement repeatability: results from the multi-national T 1 mapping standardization phantom program (T1MES). J Cardiovasc Magn Reson. 2020;22(1):31.

    Article  PubMed  PubMed Central  Google Scholar 

  52. Kotecha T, Knight DS, Razvi Y, et al. Patterns of myocardial injury in recovered troponin-positive COVID-19 patients assessed by cardiovascular magnetic resonance. Eur Heart J. 2021;42(19):1866–78.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  53. Kawel-Boehm N, Hetzel SJ, Ambale-Venkatesh B, et al. Reference ranges (“normal values”) for cardiovascular magnetic resonance (CMR) in adults and children: 2020 update. J Cardiovasc Magn Reson. 2020;22(1):87.

    Article  PubMed  PubMed Central  Google Scholar 

  54. Schulz-Menger J, Bluemke DA, Bremerich J, et al. Standardized image interpretation and post-processing in cardiovascular magnetic resonance - 2020 update: society for cardiovascular magnetic resonance (SCMR): board of trustees task force on standardized post-processing. J Cardiovasc Magn Reson. 2020;22(1):19.

    Article  PubMed  PubMed Central  Google Scholar 

  55. Augusto JB, Davies RH, Bhuva AN, et al. Articles Diagnosis and risk stratification in hypertrophic cardiomyopathy using machine learning wall thickness measurement: a comparison with human test−retest performance. Lancet. 2021;3(1):E20–8.

    Google Scholar 

  56. Hsu LY, Natanzon A, Kellman P, Hirsch GA, Aletras AH, Arai AE. Quantitative myocardial infarction on delayed enhancement MRI. Part I: Animal validation of an automated feature analysis and combined thresholding infarct sizing algorithm. J Magn Reson Imaging. 2006;23(3):298–308.

    Article  PubMed  Google Scholar 

  57. Flett AS, Hasleton J, Cook C, et al. Evaluation of techniques for the quantification of myocardial scar of differing etiology using cardiac magnetic resonance. JACC Cardiovasc Imaging. 2011;4(2):150–6.

    Article  PubMed  Google Scholar 

  58. De Cesare A, Redheuil A, Dogui A, et al. “ART-FUN”: an integrated software for functional analysis of the aorta. J Cardiovasc Magn Reson. 2009;11(1):182.

    Article  Google Scholar 

  59. Cavalcante JL, Lima JAC, Redheuil A, Al-Mallah MH. Aortic stiffness: current understanding and future directions. J Am Coll Cardiol. 2011;57(14):1511–22.

    Article  PubMed  Google Scholar 

  60. Frydrychowicz A, Franois CJ, Turski PA. Four-dimensional phase contrast magnetic resonance angiography: potential clinical applications. Eur J Radiol. 2011;80(1):24–35.

    Article  PubMed  PubMed Central  Google Scholar 

  61. Foll D, Taeger S, Bode C, Jung B, Markl M. Age, gender, blood pressure, and ventricular geometry influence normal 3D blood flow characteristics in the left heart. Eur Hear J Cardiovasc Imaging. 2013;14(4):366–73.

    Article  Google Scholar 

  62. Eriksson J, Bolger AF, Ebbers T, Carlhäll CJ. Four-dimensional blood flow-specific markers of LV dysfunction in dilated cardiomyopathy. Eur Heart J Cardiovasc Imaging. 2013;14(5):417–24.

    Article  PubMed  Google Scholar 

  63. Fidock B, Barker N, Balasubramanian N, et al. A systematic review of 4D-Flow MRI derived mitral regurgitation quantification methods. Front Cardiovasc Med. 2019;6:103.

    Article  PubMed  PubMed Central  Google Scholar 

  64. Corrias G, Cocco D, Suri JS, Meloni L, Cademartiri F, Saba L. Heart applications of 4D flow. Cardiovasc Diagn Ther. 2020;10(4):1140–9.

    Article  PubMed  PubMed Central  Google Scholar 

  65. Vázquez M, Arís R, Aguado-Sierra J, et al. Alya red CCM: HPC-based cardiac computational modelling. In: Environmental Science and Engineering. 2015; 189–207.

  66. Sacco F, Paun B, Lehmkuhl O, et al. Left ventricular trabeculations decrease the wall shear stress and increase the intra-ventricular pressure drop in CFD simulations. Front Physiol. 2018;9:458.

    Article  PubMed  PubMed Central  Google Scholar 

  67. López-Yunta M, León DG, Alfonso-Almazán JM, et al. Implications of bipolar voltage mapping and magnetic resonance imaging resolution in biventricular scar characterization after myocardial infarction. Europace. 2019;21(1):163–74.

    Article  PubMed  Google Scholar 

  68. Santiago A, Aguado-Sierra J, Zavala-Aké M, et al. Fully coupled fluid-electro-mechanical model of the human heart for supercomputers. Int J Numer Method Biomed Eng. 2018;34(12):e3140.

    Article  PubMed  Google Scholar 

  69. Hardy R, Tilling K. Commentary: the use and misuse of life course models. Int J Epidemiol. 2016;45(4):1003–5.

    Article  PubMed  PubMed Central  Google Scholar 

  70. De Stavola BL, Nitsch D, Dos Santos SI, et al. Statistical issues in life course epidemiology. Am J Epidemiol. 2006;163(1):84–96.

    Article  PubMed  Google Scholar 

  71. Wills AK, Hardy RJ, Black S, Kuh DJ. Trajectories of overweight and body mass index in adulthood and blood pressure at age 53: the 1946 British birth cohort study. J Hypertens. 2010;28(4):679–86.

    Article  CAS  PubMed  Google Scholar 

  72. Norris T, Mansukosi L, Gilthorpe MS, et al. Distinct body mass index trajectories to young-adulthood obesity and their different cardiometabolic consequences. Arterioscler Thromb Vasc Biol. 2021;41(4):1580–93.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

We are grateful to the NSHD participants who will both participate in this study and have contribution to research over the last eight decades. We would like to thank the wider NSHD team who provided contributions to the cohort as a whole but were not directly involved in the set-up of this study. We are grateful to the staff and radiographers at Chenies Mews Imaging Centre, London who provided help in setting up the CMR protocol.

Funding

Sources of funding used for staff salaries, CMR scan costs, consumables and relevant travel costs required for data collection, analysis and interpretation: British Heart Foundation special project grant (to G.C. SP/20/2/34841). This study has undergone peer-review by the funding body. Medical Research Council (Core Unit Level Funding:—MC UU 00019/1).

Author information

Authors and Affiliations

Authors

Contributions

MW and GC designed the study, obtained funding and ethical approval for the study, wrote this manuscript and will be responsible for data collection, analysis and interpretation of the results. DF, MAF, GJ, FC, CD and LHH have assisted with pilot data collection. AH, C, AW, AR, JS and RH provided expert review of the manuscript on aspects relating to the NSHD cohort and statistical analysis. AB provided expert input on aortic flow analysis and RHD on the machine learning pipeline. JCM, PK, HX and IP provided expert input on the technical CMR aspects. PL, MO and YR provided expert input on the ECGI aspects. CM, JAS and MV provided expert input on the cardiac simulations. XT, ST and CG fabricated the CMR-ECGI vest. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Gabriella Captur.

Ethics declarations

Ethical approval and consent to participate

All participants will undergo formal written consent prior to all procedures as per our ethical approval. Ethics approval has been obtained for the study: London REC—Queens Square (Ref: 19/LO/1774). London REC—Queens Square, IRAS: 254776.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing of interests.

Study status

This study is ongoing having commenced participant recruitment.

Related articles

None.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Webber, M., Falconer, D., AlFarih, M. et al. Study protocol: MyoFit46—the cardiac sub-study of the MRC National Survey of Health and Development. BMC Cardiovasc Disord 22, 140 (2022). https://doi.org/10.1186/s12872-022-02582-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12872-022-02582-0

Keywords