Skip to main content
  • Research article
  • Open access
  • Published:

Short- and medium-term follow-up of transcatheter closure of perimembranous ventricular septal defects

Abstract

Background

Transcatheter closure of perimembranous ventricular septal defects is one of the greatest challenges in interventional cardiology. Short- and midium-term follow-up data for large samples are limited. This report presents our experience with transcatheter closure of perimembranous ventricular septal defects using an occluder.

Methods

Two hundred fifty-three patients included in the database of the Second Affiliated Hospital and Yuying Children’s Hospital from January 2011– December 2015 with transcatheter closure of perimembranous ventricular septal defects and discharged from follow-up. All patients were invited for clinical and transthoracic echocardiography, electrocardiogram, and thoracic radiography check-up.

Results

Device implantation was successful in 252 of 253 patients (99.6%). The median age was 42 months (range 27–216 months). The median follow-up duration was 36 months (range 6–60 months). The mean defect diameter was 3.5 ± 1.4 mm and the mean size of the ventricular septal defect rim below the aortic valve was 3.7 ± 1.8 mm. The mean diameter of the devices used was 4 mm. Thirty-seven patients developed arrhythmia after the procedure and recovered within 24 months; four patients had hemolysis and four had moderate tricuspid valve regurgitation. No other serious adverse event occurred during the follow-up period.

Conclusion

Transcatheter closure of perimembranous ventricular septal defects using an occluder is safe and effective in most patients.

Peer Review reports

Background

The ventricular septal defect (VSD) is one of most common congenital heart defects worldwide. Perimembranous ventricular septal defect, involve a more extensive area than normal membranous septum, also known as aortic subvalvular type. The defect is surrounded by membrane, or the upper edge is fibrous and the lower edge is muscular. With advances in imaging and screening of infants, the detection rate of confirmed cases of VSD has increased notably [1]. Almost 45% of VSDs occurring in isolation close spontaneously [2]. However, for patients with medium and larger (perimembranous or muscular) defects, surgical treatment is often recommended.

Admittedly, traditional surgical repair has yielded great results. Nevertheless, residual VSDs are frequently associated with complications, such as reoperation, infection, sternotomy scarring, and even death [3, 4]. In 1987, Lock [5] was the first to use the Rashkind double-umbrella occluder to close a VSD. Since then, transcatheter VSD closure has been used increasingly in selected patients worldwide. Nevertheless, this technique is associated with complications, such as embolization of the device, hemolysis, aortic insufficiency, and complete heart block. Although various centers in China have reported the use of interventional therapy for VSDs, few data on long-term results are available. We assessed 253 patients through periodic follow-up. In this study, we report the short- and midium-term follow-up results of transcatheter closure of perimembranous VSDs using an occluder in 253 selected patients at our medical center.

Methods

Study design

This retrospective, descriptive, non-randomized study utilized data from January 2011–December 2015 from a single medical center (The Second Affiliated Hospital and Yuying Children’s Hospital, Institute of Cardiovascular Development and Translational Medicine, Wenzhou Medical University, Wenzhou, Zhejiang). Two hundred fifty-three patients (126 males, 127 females) were included (Table 1, Additional file 2: Table S2). Informed consent was obtained from all patients or their parents. All patients had clinical and echocardiographic evidence of ventricular septal defect (VSD). The position and distance between each valve and the defect should be carefully assessed preoperatively using echocardiography.

Table 1 General Characteristics of Patients

Closure protocol

According to the guidelines for interventional therapy via catheter for congenital heart disease, all patients underwent combined intravenous anesthesia and were monitored via electrocardiogram and blood pressure and oxygen saturation measurement. The peritoneal inguinal puncture site was anesthetized locally with 2% lidocaine, and the femoral vein and femoral artery were punctured. Left and right cardiac catheterization and left ventricular and ascending aortic angiography were performed to determine the size, location, shape, and distance from the aortic valve of the defect. The femoral artery, aorta, left ventricle, VSD, right ventricle, and femoral vein were identified. A long sheath was inserted into the left ventricle along the track from the side of the femoral vein, and then fed into the appropriate sealing device in an attempt to plug the defect. Generally, the sealing device must be 1–2 mm larger than the diameter of the defect. Following closure, the patient must be monitored closely for heart murmur via auscultation, left ventricular angiography should be repeated after 15 min to check for residual shunt, and root imaging should be used to assess the presence of aortic valve regurgitation and prolapse. Following successful closure, thoracic echocardiography (TTE) should be used to monitor the occluder location and sharp, and check for residual shunt and tricuspid valve, and to assess the movement of the aortic valve.

Device details

The following occluder devices were used (Tables 2, 3, 4 and 5): the Amplatzer Membranous VSD Occluder (AGA Medical Corporation) and Amplatzer-like occluders including Membranous Symmetric VSD Occluder (SHSMA Medical Corporation, China) and Cera™ Membranous VSD (Symmetric) Occluder (ShenZhen Lifetech Scientific Inc., China).

Table 2 Embolic materials used in transcatheter embolization of VSD
Table 3 Device type, sizes and recommended sheath size of CeraTM Membranous VSD (Symmetric) Occluder
Table 4 Device type, sizes and recommended sheath size of Membranous Symmetric VSD Occluder
Table 5 Device type, sizes and recommended sheath size of Amplatzer Membranous VSD Occluder

Follow-up

Immediately following the procedure, and in months 1, 3, and 6 and years 1, 2, 3, 4, and 5 of follow-up, the shape and orientation of the device and residual shunt were reevaluated through transthoracic echocardiography, electrocardiogram, and thoracic radiography.

Statistical analysis

Continuous data were expressed as means ± standard deviations with ranges and were compared using analysis of variance (ANOVA) and the student’s t-test, while categorical data are expressed as number and percentage, and were compared using the X2-test or Fisher method. All statistical analyses were performed using commercially available software (SPSS version 11.0 for Windows; SPSS Inc., Chicago, IL, USA). P values < 0.05 were considered to be significant.

Results

Patient groups

The median age at implantation was 42 months (range 27–216 months) and the median weight was 14.75 kg (range 9.5–86 kg). All patients had continuous systolic murmurs and left-to-right shunts with enlarged left ventricular diastolic dimensions. No patient received diuretics or angiotensin-converting enzyme inhibitors before the procedure for there was not any grade II or higher cardiac dysfunction after preoperative evaluation. Transcatheter femoral venous and arterial approaches were used in all patients. The mean VSD size, measured echocardiographically, was 3.5 ± 1.4 mm. Pulmonary-to-systemic flow ratio (Qp/Qs) was 2.3 ± 0.4 (range 1.5–3.0). One patient with Down syndrome underwent transcatheter closure, and a residual shunt, hemolysis, and arrhythmia was found 24 h postoperative. A surgical operation was subsequently performed. (Tables 1 and 6, Additional file 3: Table S3).

Table 6 Procedure data

Safety and efficacy

In 252 of 253 (99.6%) procedures, defect closure was successful (Fig. 1). Stable device positioning was demonstrated by angiography and transthoracic echocardiography. Significant shunt reduction was detected in all 252 patients after successful VSD closure, and only minor residual shunts were documented. Procedural data are provided in Table 6. No increase in aortic or tricuspid valve regurgitation was observed postoperatively in any patient.

Fig. 1
figure 1

Left ventricular angiography in preoperative and 15-min postoperative. a Left ventricular angiography showed the defect with the rim of 3.5 mm (the shunts was designated by arrow); b The 5 mm occluder closed the defect without residual shunt

Valve regurgitation and residual shunt

Pre-operatively, four patients had moderate tricuspid valve regurgitation and nine had mild aortic valve regurgitation. No significant increase or new regurgitation of the aortic or tricuspid valve occurred during or after the procedure. All cases of valve regurgitation had resolved without treatment at the 2-year follow-up evaluation (Fig. 2).

Fig. 2
figure 2

Echocardiography: four-chamher view with VSD, from preoperative to 2 years follow-up (26-month-old patient). VSD:ventricular septal defect; occluder: the device closed the defect without residual shunt. a: preoperative(d = 3.5 mm); b: at 1 month after the procedure; c: at 3 months after the procedure; d: at 6 months after the procedure; e: at 1 year after the procedure; f: at 2 years after the procedure

Closure was achieved with the device in all but one patient. In this case, echocardiography revealed a significant shunt at the center and edge of the occluder, and thoracic surgery was performed. Immediate complete occlusion, determine by angiography, was achieved in 38.6% of patients. Echocardiography performed 24 h postoperatively documented an occlusion rate of 86.6% (219 patients). Echocardiography confirmed the achievement of complete closure in the remaining patients, excluding the patient with a significant shunt described above, at 1 month (n = 11), 3 months (n = 3), 6 months (n = 7), 1 year (n = 1), and 2 years (n = 1) postoperatively. The occlusion rate at 2 years postoperatively was 96% (Fig. 3).

Fig. 3
figure 3

Complete closure percentage immediately on angiography and 24 h, 1 month, 3 months, 6 months, 1 year and 2 years follow up by echocardiography

Cardiothoracic ratio and tricuspid valve regurgitation pressure gradient

The cardiothoracic ratio decreased gradually from 1 to 24 months postoperatively, and had become stable by the 36-month follow-up evaluation (Fig. 4; Table 7). TTE was used to measure the tricuspid valve regurgitation pressure gradient (TR-PG) for the estimation of pulmonary artery pressure. A significant decrease was detected during follow-up (Table 7).

Fig. 4
figure 4

Frontal CTR: from preoperative to 6 months follow-up (26-month-old patient). a preoperative; b at 1 month after the procedure; c at 3 months after the procedure; d at 6 months after the procedure

Table 7 Residual shunt, tricuspid valve pressure gradient and cardiothoracic ratio

Complications

No death occurred. Arrhythmia was detected in 37 patients, hemolysis in 4, moderate tricuspid valve regurgitation in 4, and mild aortic valve regurgitation in 9 patients directly after implantation or during follow-up. No significant complication, such as procedure-related obstruction, cardiac tamponade, thrombosis or air embolism, aortic rupture, or increased valve failure, was observed. One significant complication occurred in a 3-year-old boy, who developed hematuria; significant shunt reduction and complete right bundle branch block were detected.

Hemolysis

No significant hemolysis necessitating device retrieval occurred. Although four (1.6%) patients showed erythrocyte positivity (+++) on routine urine tests during the first 24 h postoperatively, the hemolysis was not sufficiently severe in any case to warrant retrieval of the device. Blood analysis showed high values for hemolysis parameters with no relevant decrease in the hemoglobin concentration. Hemolysis regressed by 5 days postoperatively with hydration and urine alkalization. Blood transfusion was not required in any case.

Arrhythmia

Minor arrhythmic complications occurred in 37 (17.4%) patients: 14 patients had incomplete right bundle branch block and were treated with a conventional dose of methylprednisolone (20–30 ml/kg/d), which was gradually tapered. 8 had complete right bundle branch block, 3 had left bundle branch block, and 12 had left anterior fascicular block. All patients had recovered, as demonstrated by ECG, at the 24-month follow-up evaluation.

Patients with right bundle branch blocks were treated with a conventional dose of methylprednisolone (1–2 mg/kg, q8h), which was gradually tapered. As left bundle and left anterior branch blocks have been reported to lead to death due to heart failure in China, the methylprednisolone dose can be increased to 20–30 mg/kg/d to relieve ventricular septal edema.

Follow-up

VSD closure with an occluder was performed successfully in 252 patient. The patients were followed for a median follow-up period of 36 months (range 6–60 months). And the 6 months of follow-up with clinical examination, chest radiography, TTE and ECG was completed in 250 patients (250/253), 1 year in 236 (236/243), 2 years in 190 (190/208), 3 years in 151 (151/169), 4 years in 101 (101/116), 5 years in 32 (32/45) (Table 8). There were 23 patients had lost at follow-up for the following reasons: surgical follow-up for operation, patients from migrant workers’ families going back to their household registration, contact information been replaced. In addition to 9 patients who changed contact information, none of the rest of the patients lost had significant complications such as death or syncope, and they had so far insisted on regular annual follow-up at local children’s heart centers or comprehensive large hospitals. Pre- and postoperatively, TTE was used to detect the tricuspid valve pressure gradient for the estimation of pulmonary artery pressure. TTE showed that the left atrium was reduced compared with preoperative, and gradually increased during follow-up. The TR-PG decreased significantly during the postoperative follow-up period. TTE showed that the LVEDd, RV, and LA had decreased at 3 days postoperatively, decreased further at 1–6 months postoperatively, and had regressed at the 12-month follow-up examination (Table 9).

Table 8 Data of follow-up duration
Table 9 Echocardiography Follow-up Datas: preoperative and postoperative

Discussion

Ventricular septum defect (VSD) is the most common congenital heart disease, with 40 to 60% of patients with spontaneous closure, mostly in preschool children [6,7,8].

Surgical closure of VSD has always been a traditional treatment, but there are many complications [6, 9, 10]. With the continuous improvement of occluder instruments in recent years and the selection of appropriate occluder devices according to the shape and size of VSD, the interventional therapy is becoming more and more reliable, safe and effective.

Muscular and perimembranous VSDs have been closed using transcatheter devices at our center since 2002. Use of the transcatheter approach for the treatment of congenital heart diseases is appreciated by patients and their parents because of its decreased psychological impact (avoidance of a large scar), shorter hospital time, reduced pain and discomfort, and avoidance of admission to the intensive care unit [11]. In our study, the results of transcatheter VSD closure with an occluder device were satisfactory: the procedure was successful in 252 of 253 (99.6%) patients, confirming the results reported for interventional VSD closure in other published studies.

The complete VSD closure rate immediately after the procedure was 86.6%, as documented by left ventricular angiography and TTE. This rate increased to 95.3% at the 6-month follow-up evaluation and 96% at the 2-year follow-up evaluation. The follow-up was remained for those children with residual shunts, and most residual shunts resolve postoperatively. These good closure rates are similar to those obtained in other studies of transcatheter VSD closure. Residual shunt is commonly seen in cases of multiple VSDs, as the occluder size must be appropriate for complete defect coverage. Thus the location of the occlusion and the type of occluder should be flexibly selected according to the specific conditions. The general principle to achieve the goal of completely closure of the defect without affecting the function of the aortic valve and the right atrioventricular valve, as well as to reduce the occurrence of complications.

Hemolysis occurred in 4 (1.6%) patients in this study, in whom the mean VSD diameter was 8.1 ± 1.3 mm. All four of these patients had residual shunts. Postoperative hemolysis occurred in association with large defects, high shunt pressure, and residual shunt after closure. Squeezing and collision associated with rapid blood flow through the occluder can cause the mechanical rupture of red blood cells, leading to hemolysis. In these cases, aspirin was stopped and 5% sodium bicarbonate solution (5 ml/kg/d) was used for hydration and alkalization, after which three patients returned to normal after 5 days. The remaining patient developed severe hemolysis accompanied by arrhythmia and residual shunt, necessitating removal of the occluder via surgical thoracotomy.

Thirty-seven (17.4%) patients developed arrhythmia postoperatively. Patients with right bundle branch blocks were treated with a conventional dose of methylprednisolone (1–2 ml/kg, q8h), which was gradually tapered. As left bundle and left anterior branch blocks have been reported to lead to death due to heart failure in China, the methylprednisolone dose can be increased to 20–30 ml/kg/d to relieve ventricular septal edema. Conduction block is related to oppression of the left and right bundle branches due to repeated stimulation of the right ventricular surface at the defect edge by the intraoperative catheter, leading to inflammation of the marginal tissue, edema, and/or exudation. Therefore, excessive long-term intracardiac procedures should be avoided, and the occluder should be slightly larger than the defect diameter of 1–2 mm to avoid compression of the irritated edge tissue (which would lead to tissue edema), thereby preventing arrhythmia. However, evaluating patients with postoperative arrhythmia, ECG monitoring and not 24 h Holter monitoring are limited.

For valve regurgitation, valve insufficiency is associated with the use of an oversized occluder or an insufficient distance from the occluder edge to the valve. A left ventricular disc diameter of the occluder exceeding 50% of the circumference of the subaortic outflow tract has been reported to lead to outflow tract deformation, and thus to valve insufficiency [12]. Therefore, the position and distance between each valve and the defect should be carefully assessed preoperatively using echocardiography. Care should be taken during operation to avoid serious reflux or prolapse, which can damage the valve.

Postoperative follow-up chest radiography showed gradual reduction of the cardiothoracic ratio, with eventual stabilization at 50%, which is close to the normal physiological index. TTE performed immediately after occlusion and 6 months postoperatively showed gradual reduction of the left ventricular end diastolic diameter, right ventricular diameter, and left atrial diameter, indicating smaller inner diameter of the heart cavity and the restored heart structure. At the 12-month follow-up evaluation, the inner diameter indexes of patients’ hearts had increased, but were consistent with the normal developmental ranges in all age groups, suggesting the improvement of hemodynamics. The postoperative TR-PG was significantly lower than preoperatively, suggesting that the pulmonary artery pressure had decreased. The pre- and postoperative left ventricular ejection fraction values did not differ significantly, likely due to the relatively small sizes of defects in this sample.

TTE showed that the left atrium of patients was reduced compared with preoperative, and gradually increased during follow-up. Preoperative left ventricular volume overload and heart enlargement was detected with TTE; postoperatively, due to disappear shunt, the load of the heart was cut down and the heart became smaller than preoperatively. During the follow-up period, the heart became larger due to children growth. For children with growth and development, it is more intuitive to use the z-values to evaluate the heart. However, the z-values commonly used in the world are mainly applicable to Western countries such as Europe and the United States, while these are not suitable for East Asian Chinese. Recently, many centers are now gradually conducting research on the application of Z-values for children’s TTE indicators in East Asian countries such as China (Additional file 1: Table S1).

Conclusion

Transcatheter closure of VSDs is safe and effective, with a high success rate and few complications. However, indications must be strictly controlled, and the appropriate size of occluder should be selected based on angiographic findings. Patients should be monitored carefully intraoperatively via echocardiography. Further studies are needed to more fully investigate the longer term effects of this procedure.

Limitation

Holter 24-h monitoring for patients with postoperative arrhythmias is superior to ECG follow-up. Very few patients lost follow-up. Lack of normal echocardiography control.

Availability of data and materials

The datasets generated during and/or analysed during the current study are not publicly available due to protecting participant confidentiality but are available from the corresponding author on reasonable request.

Abbreviations

ECG:

Electrocardiogram

EF:

Ejection fraction

LA:

Left atrium

LVEDd:

Left ventricular end-diastolic diameter

PA:

Pulmonary artery

RV:

Right ventricular

TR-PG:

Tricuspid valve regurgitation pressure gradient

TTE:

Transthoracic echocardiography

VSD:

Ventricular septal defects

References

  1. Hoffman JI, Kaplan S. The incidence of congenital heart disease. J Am Coll Cardiol. 2002;39:1890–900.

    Article  Google Scholar 

  2. Kidd L, Driscoll DJ, Gersony WM, et al. Second natural study history of congenital hearts defects: results of treatment of patients with ventricular septal defects. Circulation. 1993;87:138–51.

    Google Scholar 

  3. Yeager SB, Freed MD, Keane JF, Norwood WI, Castaneda AR. Primary surgical closure of ventricular septal defect in the first year of life: results in 128 infants. J Am Coll Cardiol. 1984;3:1269–76.

    Article  CAS  Google Scholar 

  4. Gaynor JW, O’Brien JE Jr, Rychik J, Sanchez GR, DeCampli WM, Spray TL. Outcome following tricuspid valve detachment for ventricular septal defects closure. Eur J Cardiothorac Surg. 2001;19:279–82.

    Article  CAS  Google Scholar 

  5. Lock JE, Block PC, McKay RG, Baim DS, Keane JF. Transcatheter closure of ventricular septal defects. Circulation. 1988;78:361–8.

    Article  CAS  Google Scholar 

  6. Mavroudis C, Backer CL, Jacobs JP. Ventricular septal defect. Pediatric Cardiac Surgery. 3rd ed. Philadelphia: PAMosby; 2003.

    Google Scholar 

  7. Butera G, Chessa M, Piazza L, Negura D, Micheletti A, Carminati M. Transcatheter closure of ventricular septal defects. Expert Rev Cardiovasc Ther. 2006;4(5):671–80 Review.

    Article  Google Scholar 

  8. Kidd L, Discroll DJ, Gersony WM. Second natural history study of congenital heart defects: results of treatment of patients with ventricular septal defects. Circulation. 1993;87(2 Suppl I):138–51.

    Google Scholar 

  9. Hobbins SM, Izukawa T, Radford DJ, Williams WG, Trusler GA. Conduction disturbances after surgical correction of ventricular septal defect by the atrial approach. Br Heart J. 1979;41:289–93.

    Article  CAS  Google Scholar 

  10. Kirklin JW, Barrat-Boyes BG, Kouchoukos NT, Blacksgowe EH, Doty DB, Hawley FL, Karp RB. Ventricular septal defect. Cardiac Surgery. 3rd ed. New York: Churchill Livingstone; 1993.

    Google Scholar 

  11. Butera G, Carminati M, Chessa M, Piazza L, Micheletti A, Negura DG, Abella R, Giamberti A, Frigiola A. Transcatheter closure of perimembranous ventricular septal defects: early and long-term results. J Am Coll Cardiol. 2007;50(12):1189–95.

    Article  Google Scholar 

  12. Siddiqui WJ. Ventricular septal defect: early against late surgical repair. J Community Hosp Intern Med Perspect. 2016;17(6):30460–2.

    Article  Google Scholar 

Download references

Acknowledgements

None.

Funding

This work was supported by the Wenzhou Municipal Science and Technology Burean Funds [grant numbers Y20180262 Wenzhou, Zhejiang, China].

Author information

Authors and Affiliations

Authors

Contributions

LH and SYY contributed equally to this study. LH and SYY analyzed the data and drafted the manuscript; ZSY, RY, RX, WZQ, XTH, XHT, YYY and ZY collected and organized the data; WRZ and CMP conceived and designed the whole study. All authors have seen and approved the final manuscript.

Corresponding authors

Correspondence to Maoping Chu or Rongzhou Wu.

Ethics declarations

Ethics approval and consent to participate

This was a retrospective review of cases of patients treated at the Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University. All participant received were considered standard care for their condition. The treatment these patients received was considered standard care for their condition. The Ethics Committee of the Second Affiliated Hospital of Wenzhou Medical University approved this retrospective study, and all patients provided written informed consent before the procedure and gave consent for their information to be used for this study.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

This author is responsible for all aspects of reliability and all data biases and interpretation of the discussion.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Additional files

Additional file 1:

Table S1. Echocardiography Follow-up Datas: preoperative and postoperative. (DOCX 16 kb)

Additional file 2:

Table S2. Size of Perimembranous ventricular septal defect. (DOCX 15 kb)

Additional file 3:

Table S3. Data for pulmonary artery pressure. (DOCX 15 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Li, H., Shi, Y., Zhang, S. et al. Short- and medium-term follow-up of transcatheter closure of perimembranous ventricular septal defects. BMC Cardiovasc Disord 19, 222 (2019). https://doi.org/10.1186/s12872-019-1188-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12872-019-1188-y

Keywords