Skip to main content

Table 5 Postoperative Echocardiographic outcomes

From: Sutureless Biological Aortic Valve Replacement (Su-AVR) in Redo operations: a retrospective real-world experience report of clinical and echocardiographic outcomes

 

Conventional AVR (cAVR) (Perimount) (n = 52)

Sutureless AVR (su-AVR) (Perceval) (n = 27)

P-value

Post Discharge

Left Ventricular Functions

  

0.826

 EF good

75.6 (31)

79.1 (19)

 

 EF moderate

22.0 (9)

16.7 (4)

 

 EF poor

2.4 (1)

4.2 (1)

 

 EF%

56.8 ± 10.0

56.1 ± 11.4

0.537

Prosthesis Functions

  

0.714

 Normally functioning

82.8 (34)

87.5 (21)

 

 Mild AR

14.6 (6)

8.3 (2)

 

 Moderate AR

0.0 (0)

4.2 (1)

 

Severe AR

0.0 (0)

0.0 (0)

 

Aortic Valve Gradient

Peak

23.2±10.6

30.5±14.8

0.026

Mean

12.9±6.4

16.7±8.4

0.045

Under 20 mm Hg

85.4 (35)

75.0 (18)

 

20–39 mm Hg

14.6 (6)

25.0 (6)

 

40- mm Hg

0.0 (0)

0.0 (0)

 

Late Term Follow-up (median 24 month)

Left Ventricular Functions

EF good

93.9 (31)

90.0 (18)

 

EF moderate

6.1 (2)

10.0 (2)

 

EF poor

0.0 (0)

0.0 (0)

 

EF%

60.4±6.8

58.5±9.2

0.391

Prothesis Functions

  

0.116

Normally functioning

87.9 (29)

70.0 (14)

 

Mild AR

12.1 (4)

20.0 (4)

 

Moderate AR

0.0 (0)

10.0 (2)

 

Severe AR

0.0 (0)

0.0 (0)

 

Aortic Valve Gradient

Peak

12.9±7.1

15.6±13.6

0.360

Mean

22.8±12.3

22.8±13.6

0.997

Under 20 mm Hg

48.4 (15)

52.6 (10)

 

20–39 mm Hg

41.9 (13)

42.1 (8)

 

40- mm Hg

9.7 (3)

5.3 (1)