Skip to main content

Table 3 Procedural characteristics

From: Clinical outcomes of an ultrathin-strut sirolimus-eluting stent in all-comers population: Thailand Orsiro registry

 

All population

n = 150, L = 235

Diameter stenosis, %

84.9 ± 11.8

Pre-dilation

 

 Pre-dilatation

217(91.9)

 Cutting or scoring balloon

10(4.2)

 Non-compliance balloon

35(14.8)

 Semicompliance balloon

171(72.5)

 Nominal pre-dilation balloon diameter, mm

2.49 ± 1.00

 Pre-dilation balloon length, mm

17.1 ± 4.9

Stent procedure

 

 No. of study stents implanted

 

  Per patient

1.7 ± 1.1

  Per lesion

1.1 ± 0.3

  Per vessel

1.4 ± 0.7

 Total length of implanted stents, mm

26.9 ± 12.2

 Mean nominal device diameter, mm

2.97 ± 0.46

 Overlapping stents

18(7.6)

 Bifurcation lesions treated with provisional stenting

47(95.9)

 Bifurcation lesions treated with two-stent technique

2(4.1)

 Number of stents per lesion

 

  1

217(92.3)

  2

16(6.8)

  3

1(0.4)

  4

1(0.4)

Intracoronary imaging in the procedure

16(6.8)

Post-dilation

 

 Post-dilation

165(69.9)

 Nominal post-dilation balloon diameter, mm

3.12 ± 0.53

 Post-dilation balloon length, mm

15.5 ± 6.2

 NC used for post-dilation

110(67.1)

 Max applied pressure, atm

16.5 ± 4.0

 Cumulative inflation time

23.0(13.3–38.8)

Device success

235(100)

Procedure success

147(98.0)

  1. Data shown in n(%) or mean ± SD or median (interquartile range 1st–3rd)