Table 1 Baseline characteristic of aortic valve variants

From: Assessment of aortic valve in regard to its anatomical variants morphology in 2053 patients using 64-slice CT retrospective coronary angiography

ANNULUS
Parameter UAV
(n = 1)
BAV 0
(n = 5)
BAV 1
(n = 14)
TAV
(n = 24)
QAV
(n = 1)
Mean [mm2] 835,00 730,40 696,00 546,71 756,00
SD [mm2] - 198,00 227,12 96,23 -
Min [mm2] 835,00 380,00 404,00 413,00 756,00
Max [mm2] 835,00 848,00 1223,00 713,00 756,00
ORIFICE
Parameter UAV
(n = 1)
BAV 0
(n = 5)
BAV 1
(n = 14)
TAV
(n = 24)
QAV
(n = 1)
Mean [mm2] 262,00 401,20 329,43 357,96 562,00
SD [mm2] - 293,96 167,53 76,85 -
Min [mm2] 262,00 165,00 176,00 239,00 562,00
Max [mm2] 262,00 765,00 774,00 493,00 562,00
INDEX = (Annulus - Orifice)/Annulus
Parameter UAV
(n = 1)
BAV 0
(n = 5)
BAV 1
(n = 14)
TAV
(n = 24)
QAV
(n = 1)
Mean [−] 0,69 0,46 0,52 0,34 0,26
SD [−] - 0,32 0,18 0,11 -
Min [−] 0,69 0,09 0,02 0,06 0,26
Max [−] 0,69 0,79 0,73 0,55 0,26
ORIFICE/ANNULUS
Parameter UAV
(n = 1)
BAV 0
(n = 5)
BAV 1
(n = 14)
TAV
(n = 24)
QAV
(n = 1)
Mean [−] 0,31 0,54 0,48 0,66 0,74
SD [−] - 0,32 0,18 0,11 -
Min [−] 0,31 0,21 0,27 0,45 0,74
Max [−] 0,31 0,91 0,98 0,94 0,74
ASCENDENS
Parameter UAV
(n = 1)
BAV 0
(n = 5)
BAV 1
(n = 14)
TAV
(n = 24)
QAV
(n = 1)
Mean [mm] 54,00 35,20 43,29 30,88 39,00
SD [mm] - 9,36 10,06 2,76 -
Min [mm] 54,00 24,00 27,00 27,00 39,00
Max [mm] 54,00 46,00 70,00 38,00 39,00
  1. BAV – biscupid aortic valve, UAV – unicuspid aortic valve, QAV – quadricuspid aortic valve, TAV – tricuspid aortic valve, Index - (annulus - orifice)/annulus