Skip to main content

Table 1 CT acquisition and reconstruction parameters in three cohorts

From: Comparison of epicardial adipose tissue volume quantification between ECG-gated cardiac and non-ECG-gated chest computed tomography scans

Paired CT dataset

Cohort 1 (N = 49)

Cohort 2 (N = 34)

Cohort 3 (N = 32)

ECG-gated Cardiac NCCT

Non-ECG-gated Chest NCCT

ECG-gated Cardiac NCCT

Non-ECG-gated Chest NCCT

Non-ECG-gated Chest NCCT

Non-ECG-gated Chest arterial CECT

Non-ECG-gated Chest venous CECT

ECG gate

Yes

No

Yes

No

No

No

No

Field of view

150 ~ 170 × 150 ~ 170 mm

360 × 300 ~ 360 mm

150 ~ 170 × 150 ~ 170 mm

360 × 300 ~ 360 mm

360 × 300 ~ 360 mm

360 × 300 ~ 360 mm

360 × 300 ~ 360 mm

Matrix size

512 × 512

512 × 512

512 × 512

512 × 512

512 × 512

512 × 512

512 × 512

Tube voltage (kVp)

120

120

120

100

120

120

120

Contrast given

No

No

No

No

No

Yes, arterial phase

Yes, venous phase

Collimation (mm)

128 × 0.6

128 × 0.625

128 × 0.6

128 × 0.625

128 × 0.625

128 × 0.625

128 × 0.625

Gantry rotation time (ms)

330

350

330

350

350

350

350

Pitch

0.24

1.2

0.24

1.2

1.2

1.2

1.2

Reconstructed slice thickness (mm)

3

1.25 and 5

3

1.25 and 5

1.25 and 5

1.25 and 5

1.25 and 5

  1. ECG, electrocardiogram, NCCT, non-contrast computed tomography, CECT, contrast-enhanced computed tomography