Skip to main content

Table 2 Procedural outcomes of the study population

From: A CT-based technique to predict optimal projection for self-expanding TAVI in patients with different aortic valve anatomies

Procedural outcomes, %(n)

All(n = 331)

TAV(n = 206)

BAV(n = 125)

Successful THV implantation

100 (331)

100 (206)

100 (125)

Major vascular complication

2 (7)

2.4 (5)

1.6 (2)

Major bleeding

1.2 (4)

0.5 (1)

2.4 (3)

New onset permanent pacemaker

24.8 (82)

27.2 (56)

20.8 (26)

In-hospital stroke

0.3 (1)

0.5 (1)

0

Moderate or severe paravalvular leak

0.6 (2)

0.5 (1)

0.8 (1)

  1. THV transcatheter heart valve