Table 1 Size of the guide extension catheter and the rotaburr that can be used with the “mother-and-child” technique

From: The rotational atherectomy with a guide extension catheter for calcified and tortuous lesions in left anterior descending artery: a case report

Guide extension catheter

Size (Fr)

Inner lumen diameter (mm)

Outer lumen diameter (mm)

Maximum possible burr size (mm)

Maximum burr size within recommended range* (mm)

Guidezilla II (Boston Scientific)

6.0

1.45

1.70

1.25

1.25

7.0

1.60

1.85

1.50

1.50

8.0

1.83

2.11

1.75

1.50

Guideliner V3 (Lifeline)

5.5

1.30

1.64

1.25

N/A

6.0

1.42

1.70

1.25

1.25

7.0

1.57

1.90

1.50

1.25

Guideplus (Nipro)

6.0

1.33

1.76

1.25

N/A

Hikyaku (Kaneka)

6.0

1.48

1.75

1.25

1.25

Telescope (Medtronic)

6.0

1.42

1.71

1.25

1.25

7.0

1.57

1.90

1.57

1.25

  1. *The recommended burr size is 0.1 mm smaller than the inner lumen diameter of the guide extension catheter