Table 4 Comparisons between pre- and post-occlusion parameters

From: Transcatheter closure for patent ductus arteriosus in patients with Eisenmenger syndrome: to do or not?

Patient (no.)

PDA diameter (mm)

Occluder size (mm)

PA (mmHg)

AO (mmHg)

SaO2 (%)

Pre-

Post-

Pre-

Post-

pre-

post-

SP

DP

MP

SP

DP

MP

SP

DP

MP

SP

DP

MP

1

10

18–20

105

54

72

56

34

43

113

73

85

124

86

108

96

98

2

9

16–18

110

61

84

61

44

53

123

69

94

116

69

91

97

100

3

9

20–22

138

58

88

74

27

46

137

67

89

150

70

100

92

100

4

11

20–22

145

72

104

72

30

48

144

78

102

153

91

116

97

100

  1. PDA patent ductus arteriosus, PA pulmonary artery, AO aorta, SP systolic pressure, DP diastolic pressure, MP mean pressure, SaO2 systemic arterial oxygen saturation