From: Endovascular repair of late type IIIb endoleak after endovascular aneurysm repair: a case report
Patient | 1 | 2 | 3 |
---|---|---|---|
Gender&Age | 90, Male | 79, Famle | 75, Male |
Past History | Hypertension | Hypertension | Hypertension |
Smoking | Diabetes | post-CABG | |
 |  | Smoking | |
 |  | Endoleak repair once 3 years prior (detail unknown) | |
EVAR Stent | Talent, Medtronic; Body:24 × 14 × 155 mm, limb: 14 × 14 × 75 mm | Aegis-B, MicroPort; (unibody design) Body: 24 × 80 mm, limbs: 12 × 40 mm, 12 × 30 mm | Unknown |
Years of Repair after EVAR | 4 | 3 | 6 |
Repair Device | (1) Ankura 34 × 34 × 40 mm, Lifetech (2) Ankura 34 × 34 × 60 mm, Lifetech (3) Excluder 32 × 32 × 40 mm, Gore | Endurant II, Medtronic; Body: 25 × 16 × 145 mm, iliac limb: 16 × 13 × 80 mm | Excluder 12 × 12 × 100 mm, Gore |
Follow-up | 4 times/4 years | 2 times/2 years | 2 times/2 years |
Recurrence or Related Complication | No | No | No |