Skip to main content

Table 3 The effect of repeated INR level and event outcome measures at time

From: Optimal INR level for warfarin therapy after mechanical mitral valve replacement

 

Mean INR

Standard error of mean

Mean difference (95% CI)

Effect Estimate (Beta)

Effect Standard Error

P-value

Thromboembolic

1.69

0.11

−0.86

−0.88

0.19

< 0.001

No Thromboembolic

2.55

0.01

(−1.24 to − 0.49)

   

Bleeding

5.05

0.53

2.53

2.52

0.154

< 0.001

No bleeding

2.53

0.01

(2.22 to 2.83)

   

Major

4.95

0.76

2.41

2.41

0.22

< 0.001

No major

2.54

0.01

(1.97 to 2.85)

   

Minor

5.16

0.79

2.63

2.61

0.22

0.002

No minor

2.54

0.01

(2.19 to 3.06)

   

Follow-up time point

   

0.004

0.003

0.121

  1. The interaction effect between Thromboembolic, bleeding, minor bleeding and major bleeding event and time was non-significant (P-value > 0.05)