Skip to main content

Table 2 Procedural characteristics of the study population

From: Endothelial progenitor cells and plaque burden in stented coronary artery segments: an optical coherence tomography study six months after elective PCI

Characteristics

n = 44 lesions

 

mean ± SD or N (%)

BASELINE

 Reference lumen diameter (mm)

2.62 ± 0.34

 Minimal lumen diameter (mm)

0.66 ± 0.4

 Stenosis (%)

74.5 ±13.9

 Stent type: BMS / DES

25 (56.8%) / 19 (43.2%)

 Stent length (mm)

19. 8 ± 4.9

  ≥ 2 stents

5 (11.4%)

 Stent diameter (mm)

2.82 ± 0.24

 Ostial lesion

3 (6.8%)

 Chronic total occlusion

9 (20.5%)

 Lesion type (AHA/ACC) A/B/C

0 / 32 (72.7%) / 12 (27.3%)

 Target vessel RCA/LCX/LAD

14 (31.8%) / 10 (22.7%) / 20 (45.5%)

 Fluoroscopy time (min)

11.6 ± 10.5

FOLLOW-UP

 Follow-up interval (days)

188.4 ± 20.0

 Minimal lumen diameter (mm)

2.1 ± 0.4

 Diameter Stenosis (%)

21.1 ± 12.5

  1. BMS bare metal stent, DES drug-eluting stent, RCA right coronary artery, LCX left circumflex, LAD left anterior descending, SD standard deviation