Skip to main content

Table 2 Quality of focused cardiac ultrasound by nurses

From: Screening for rheumatic heart disease: quality and agreement of focused cardiac ultrasound by briefly trained health workers

View

Quality

Nurse 1

 

Nurse 2

 

Nurse 3

 

Nurse 4

 

Nurse 5

 

Nurse 6

 

Nurse 7

 

Total

 

n = 250

n = 264

n = 340

n = 340

n = 274

n = 311

n = 239

n = 2018

  

n

%

n

%

n

%

n

%

n

%

n

%

n

%

n

%

Overall

1

248

99.2

216

81.8

338

99.4

337

99.1

266

97.1

308

99.0

236

98.7

1949

96.6

2

2

0.8

42

15.9

0

0.0

2

0.6

7

2.6

3

1.0

2

0.8

58

2.9

3

0

0.0

6

2.3

2

0.6

1

0.3

1

0.4

0

0.0

1

0.4

11

0.5

MV 2D

1

247

98.8

204

77.3

337

99.1

337

99.1

265

96.7

308

99.0

235

98.3

1933

95.8

2

3

1.2

59

22.3

1

0.3

3

0.9

9

3.3

3

1.0

4

1.7

82

4.0

3

0

0.0

1

0.4

2

0.6

0

0.0

0

0.0

0

0.0

0

0.0

3

0.2

MV CD

1

249

99.6

210

79.5

337

99.1

334

98.2

256

93.4

308

97.1

228

95.4

1916

94.9

2

1

0.4

48

18.2

1

0.3

5

1.5

17

6.2

3

2.9

10

4.2

91

4.5

3

0

0.0

6

2.3

2

0.6

1

0.3

1

0.4

0

0.0

1

0.4

11

0.5

AV 2D

1

244

97.6

215

81.4

329

96.7

325

95.6

268

97.8

302

99.0

236

98.7

1925

95.4

2

6

2.4

49

18.6

9

2.7

15

4.4

5

1.8

9

1.0

3

1.3

90

4.5

3

0

0.0

0

0.0

2

0.6

0

0.0

1

0.4

0

0.0

0

0.0

3

0.1

AV CD

1

248

99.2

224

84.8

338

99.4

340

100.0

266

97.1

308

99.4

236

98.3

1960

97.1

2

2

0.8

38

14.4

0

0.0

0

0.0

7

2.6

3

0.6

3

1.7

53

2.6

3

0

0.0

2

0.8

2

0.6

0

0.0

1

0.4

0

0.0

0

0.0

5

0.3

  1. Quality: 1, adequate for diagnosis; 2, poor but diagnosis made; 3, not interpretable. AV aortic valve, MV mitral valve, 2D two-dimensional mode, CD color Doppler mode