Skip to main content

Table 3 Speckle tracking echocardiography derived peak LV circumferential and longitudinal strain and strain rate of T1DM patients and healthy controls

From: The influence of real-time blood glucose levels on left ventricular myocardial strain and strain rate in pediatric patients with type 1 diabetes mellitus - a speckle tracking echocardiography study

 

Type 1 diabetes mellitus

Control

p-value

Blood glucose level <150 mg/dl

Blood glucose level >150 mg/dl

 

(n = 17)

(n = 22)

(n = 44)

Circumferential strain

-24.24 ± 3.11

-28.81 ± 4.84

-25.95 ± 3.92

0.003

Circumferential strain rate

-1.96 ± 0.26

-2.12 ± 0.40

-1.86 ± 0.25

0.005

Global longitudinal strain

-19.55 ± 2.27

-20.57 ± 2.41

-20.72 ± 2.49

n.s.

Global longitudinal strain rate

-1.51 ± 0.26

-1.85 ± 0.51

-1.55 ± 0.21

0.002

  1. p-values are calculated with one way ANOVA and post hoc test, level of significance = 0.00625